Jacto DJB-20S Manual Del Operador página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DROPLET SIZE
VF
Very Thin
F
Thin
M
Medium
C
Course
VC
Very course
XC
Extremely course
WARNING!
Use PPE to service and replace parts.
9.2. Pressure, flow rate and autonomy of each nozzle
type
Nozzle
Level
Pressure (psi)
Min.
01
Med.
(ORANGE)
Max.
Min.
015
Med.
(GREEN)
Max.
Min.
02
Med.
(YELLOW)
Max.
Min.
025
Med.
(PURPLE)
Max.
Min.
03
Med.
(BLUE)
Max.
Min.
04
Med.
(RED)
Max.
NOTE*: Nozzle has not reached working pressure (15 psi).
NOTE**: The values above may vary as to the wear, clogging and variation of the
nozzles, the density and viscosity of the liquid to be applied, the temperature and
relative humidity of the environment, the altitude and consequent atmospheric
pressure of the site, the height of the lance spraying, etc.
NOTE***: The minimum working nozzle pressure should always be observed, so
we do not recommend spraying at pressures below 15 psi for fan nozzles and
below 45 to 60 psi for conical nozzles depending on the model. In addition, we
do not recommend using ISO standard nozzles of brown color (05 gal/min at 3
bar pressure).
9.3. Electronic panel
The electronic panel that controls Jacto DJB-S functions has two buttons and a
display. Through its interface, it is possible to see the equipment's battery level,
choose the desired dose function, pressure and volume, as well as some features
that will be shown below.
Flow rate
Autonomy
(L/min)
30
0,38
13,0
46
0,44
61
0,50
20
0,48
14,3
35
0,59
49
0,69
15
0,58
14,6
27
0,72
39
0,84
15
0,78
10,7
23
0,87
32
0,96
15
0,85
20
0,95
25
1,05
N/A *
N/A *
N/A *
N/A *
N/A *
N/A *
16
1,19
When operating the equipment, the following audible/visual warnings may be
issued if a fault is detected:
• Three short beeps repeated at every five seconds and an error message on the
display = critical fault in the pump, motor or wiring. Contact Technical Support.
(h)
8,9
5,6
8,8
5,5
• Five short beeps repeated at every thirty seconds and an error message on
8,5
the display = low battery (only a few minutes of operation left). Recharge as
5,6
soon as possible.
7,5
5,7
9,8
7,2
5,9
6,2
• An error message on the display = battery overvoltage (user tried to connect
a battery different from the original one). If the battery voltage is too high,
the electronic interface will be completely shut down to prevent permanent
damage.
9.4. Jacto Smart Control App
For a complete experience, use Jacto Smart Control App. Control, calibrate and
manage your applications on your Smartphone.
Download our App from www.jacto.com/smartcontrol
Display
VOLUME:5 ml
ON button
OFF button
PRES.
BAT.
BAT.