Controller Operation
The KD2 controller has five modes of operation:
Automatic, Manual Station(s), Manual Programs, Test and
Off. In the Automatic mode, the controller tracks the time
and day and operates the automatic watering schedules
as programmed. The Manual Station(s) mode enables an
individual station or group of stations to be started and
controlled manually. Manual Programs mode enables
watering programs to be started manually. Test mode
enables a quick, temporary program to be run to test the
operation of each station control valve. The Off mode
prevents all station operation.
Automatic Operation
Automatic operation will occur whenever the programmed
start time and watering day matches the KD2's internal
clock and calendar.
The
HOME control dial position is the normal position
for the dial when automatic operation is desired. However,
the controller will operate automatically when the control
dial is in any position.
While an automatic watering program is running and the
HOME position, pressing the
control dial is in the
button will manually advance from the activate station to
the next displayed station number in sequence
14
Manual Operation
Manual controller operations will override all currently
active automatic operation and sensor input. Any
automatic program start time that occurs during a manual
operation will be delayed until the manual operation is
terminated or concluded. Any automatic program delayed
past midnight will be postponed.
True Manual Operation
True manual operation allows a single station to be
selected and run without regard to run time duration.
Once started, the station will run until it is turned off or the
controller clock time passes midnight.
1. Turn the control dial to
2. Press the
button until the desired station number is
flashing and the display shows - - - - - - (dashes).
3. Press the
button once to activate the station. The
station number and ON will be displayed along with
the flashing watering symbol
Manual Station position. The station will remain on
until operation is terminated or until midnight.
• To terminate operation prior to midnight, turn the
control dial to any other position or press any button.
4. Return the control dial to
finished.
Manual Station position.
. Leave the dial in the
HOME position when