revised 1/12
MAINTENANCE SCHEDULE
TASK
Flush tank out with clean water
Flush dump pump out with clean water
Check/Clean Electronic Float
Check/Clean Ball Floats at Vacuum Inlets in Recovery Tank
*Check Carbon Brushes
*Have a US Products service technician check the vacuum motor brushes once a year or after 300 operating hours.
GENERAL TROUBLESHOOTING
IF THIS
Pump or Vac Does Not Turn On
Dump Pump Not Discharging
Pump Pressure is Low
Vacuum Suction is Low
Water Leaking from Pump
Oil Leaking from Pump
TECHNICAL SPECIFICATIONS (as installed and tested on the unit)
MODEL
POWER CORD:
POWER CONSUMPTION:
RECOVERY CAPACITY:
VACUUM INTAKE HOSE:
VACUUM MOTOR(s):
WATER LIFT/CFM:
AIR WATTS:
OVERFLOW PROTECTION:
HIGH PRESSURE PUMP
DISCHARGE PUMPS:
DISCHARGE HOSE:
DISCHARGE RATE:
FILTER SYSTEM:
WEIGHT
1/12
CHECK THIS
Check the circuit breakers in the wall. If both cords were on one circuit the breaker may
have tripped.
The switches should light up when turned ON. Check the switch to make sure it is
working.
Check the circuit breakers in the wall. If both cords were on one circuit the breaker may
have tripped.
The switches should light up when turned ON. Check the switch to make sure it is
working.
Check electronic fl oat to make sure it is not obstructed and moving freely.
Check the spray tip(s) for proper size or excessive wear.
The pressure relief valve may be stuck open, or the seat may be worn.
Check the inlet fi lters for dirt or debris.
The pump inlet or outlet valves may be dirty or damaged.
Make sure the tank lid is closed tightly, the drain hose is closed tightly, and the recovery
hose is tight at the vac inlet hose barb and at the tool.
Check the hose for cracks.
Worn packing in pump.
Worn piston seals.
Misaligned oil seal O-Ring.
Bad bearing.
Damaged crankcase.
TORRENT
Two, 25 ft, 12 gauge, 3-wire with hospital grade
plug
15 Amps, each cord
9 gallon
1.5" inch X 25 ft
Two, 3-stage
100 inches / 170 cfm
520 AW in operational range
Electronic fl oat; auto off/on
Triplex Plunger Pump, Adjustable 1200-400 psi
working pressure,
One diaphragm bilge pumps
One 3/4 inch X 50 ft
5.2 GPM
One 80 micron mesh strainer at water inlet on
recovery tank; One 60 mesh S/S fi lters in the
recovery tank
145 LBS
INSTRUCTIONS FOR USE
DAILY
WEEKLY
X
X
X
X
56380561
Two, 25 ft, 12 gauge, 3-wire with hospital grade plug
15 Amps, each cord
9 gallon
1.5" inch X 25 ft
Two, 3-stage
100 inches / 170 cfm
520 AW in operational range
Electronic fl oat; auto off/on
Triplex Plunger Pump, Adjustable 1200-400 psi
working pressure,
One diaphragm bilge pumps
One 3/4 inch X 50 ft
5.2 GPM
One 80 micron mesh strainer at water inlet on
recovery tank; One 60 mesh S/S fi lters in the
recovery tank
145 LBS
56041839 - TORRENT
ENGLISH - A
YEARLY
X
A - 9