Important
Those authorised to carry out the connection
operation must have experience acquired and
certifi ed in the specifi c sector, in accordance
with current legislation in the appliance's in-
stallation country.
The connection must make to the proper
standards and must comply with all the rele-
vant regulations and legislation.
The appliance is supplied with operating volt-
age 230V/1N 50Hz ( Selector switch allowed
60Hz, see electrical system diagram).
Caution - Warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity
supply as follows:
If not already present, install an automatic
1)
circuit-breaker
the following characteristics:
GB
3269830_inst_GB_rev.2
ELECTRICAL CONNECTION
, close to the appliance, with
(A)
B
– Thermal breaker device (to adjust see table
Annexes).
– Magnetic circuit breaker curve B (IEC 60898-1).
– Residual current protection set at mA 30.
Open the hatch (B).
2)
Undo the screws to remove the drain lever
3)
(C).
Undo the screws to remove the pane
4)
Connect the circuit-breaker (A) to the terminal
5)
board
diagram and in the electrical system diagram
at the back of the manual. Use a cable with at
least H05RN-F characteristics. Tighten the cable
gland (
– Weight: ≥ than H05RN-F type (designation 245
IEC 57)
– Temperature of use: ≥ 70°C.
Important
When connecting, take care to connect the
neutral and earth lines.
Tighten the cable gland (H).
6)
Replace all when the operation is complete.
7)
D
G
H
C
- 12 -
of the appliance as shown in the
(G)
H).
A
.
(D)
ENGLISH