INSTRUCTIONS FOR USE

Before starting crimping operations, the following parts of the manual must be read very
carefully :
MACHINE CHARACTERISTICS
SAFETY REGULATIONS
LIGHTING
PRELIMINARY CHECKS AND START-UP
DESCRIPTION OF CONTROLS
SELECTION AND REPLACEMENT OF THE CLAMPS.
1. Decide the final crimp diameter required (the final crimp diameter is supplied by the
producers of the unions; follow their instructions) and insert the proper set of clamps
(table B – page 41).
2. Insert the hose with the union and bush, already prefitted, between the clamps.
Attention: after turning the master switch, wait a few seconds while the
power supply is loading.
"Power switch"
3. Turn the
4. Bear in mind that every millimeter of advancement of the knurled handwheel (item 1,
fig. 3) on the graduated rod (item 2, fig. 3) corresponds to ± 1 millimetre of variation
on the clamp closing. When the knurled handwheel is in position 0 on the graduated
rod, the final diameter corresponds to the nominal diameter of the clamp which is
printed on it. Each notch of the knurled handwheel corresponds to ± 0.1 mm on the
diameter.
Example: in order to obtain a final diameter of 12 mm, use a clamp with size
10. Considering that the difference between the two diameters is 2 mm, the
knurled handwheel should be turned twice completely, so as to be positioned
at no. 2 of the graduated rod.
5. After setting the crimp diameter press the "Close" button and wait for the piston stroke
to come to its end and stop automatically.
6. Press the "Open" button to make the piston back up, and remove the joined pipe.
N.B. THE MACHINE IS EXTINGUISHED AUTOMATICALLY AFTER 15 MINUTES IF NOT
USED
Start
and press the "
" button.