ALARM Menu
This menu sets the alarm settings.
A L A R M
A L A R M H A N D L I N G : O F F
P O R T 1 : N O
P O R T 2 : N O
P O R T 3 : N O
P O R T 4 : N O
P O R T 5 : N O
P O R T 6 : N O
P O R T 7 : N O
P O R T 8 : N O
P R E / P O S T A L A R M. . .
< C A N C E L > < O K >
ALARM HANDLING
Set ON to change the display to show an image from
the camera with the alarm.
Note
If ALARM HANDLING has been set to OFF, the
camera will not be switched by the second or later
alarm inputs.
PORT1 – PORT8
Displays the alarm input polarity and alarm names.
You can name (up to 17 characters) the ports to
identify the connections between the ports and the
connected devices. Set the name as follows.
1
Move the cursor to the port number to be named
and press ENTER.
2
Select the alarm input polarity. Each time you
press b, the setting is changed as follows.
NO (Normal Open) n NC (Normal Close) n
DISABLE (Disable)
3
Press v. Enter the alarm name.
The ALARM menu screen appears.
2-12
(GB)
Chapter 2 Setup Using the SETTING Menu
PRE/POST ALARM REC
You can record the still images immediately before or
after the alarm. You can also set the interval of the
recording of the still images.
P R E / P O S T A L A R M
A L A R M N A M E :
A L A R M R E C K I N D : N O N E
R E C I N T E R V A L
: [ 2. . .]
P R E A L A R M N O
: [ 1 ]
0 1 2 3 4 5 6 7 8 9 BS
< C A N C E L > < O K >
ALARM NAME: Displays the alarm name.
ALARM REC KIND: Select the alarm recording
type. Each time you press b, the setting is
changed as follows.
PRE-ALARM (pre alarm) n POST-ALARM
(post alarm) n NONE (none)
REC INTERVAL: Set the interval of the still
images (1 – 99 seconds).
PRE ALARM NO: You can set only one video input
for PRE-ALARM. Set the alarm port number.
(The alarm corresponds to the video input.)
When the PRE/POST ALARM REC KIND is set to
PRE-ALARM or POST-ALARM, the camera numbers
are defined as follows.
Camera number
PRE ALARM
250
QUAD
251
TIME –
252
TIME 0
253
TIME +
254
TIME ++
The PRE ALARM REC images (TIME–, TIME0,
TIME+, TIME++) are placed clockwise starting with
TIME–, but the position of TIME– is not fixed.
The POST ALARM REC images are placed as shown
below.
TIME0
LIVE
POST ALARM
QUAD
TIME 0
TIME 1
TIME 2
LIVE
TIME1
TIME2