Level Range
1. Place level on the oven bottom, as indicated in one of the
two figures below, depending on the size of the level.
Check with the level side to side and front to back.
2. If range is not level, use a wrench or pliers to adjust leveling
legs up or down until the range is level.
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
This range is factory set for use with Natural gas. To use
this range with Propane gas, see the "Gas Conversions"
section before connecting this range to the gas supply. Gas
conversions from Natural gas to Propane gas or from Propane
gas to Natural gas must be done by a qualified installer.
Typical Flexible Connection
1. Apply pipe-joint compound made for use with Propane
gas to the smaller thread ends of the flexible connector
adapters. See B and G in the following illustration.
2. Attach one adapter to the gas pressure regulator and
the other adapter to the gas shut-off valve. Tighten
both adapters, being certain not to move or turn the gas
pressure regulator.
10
3. Use a 15/16" (24 mm) combination wrench and an
adjustable wrench to attach the flexible connector to
the adapters.
IMPORTANT: All connections must be wrench-tightened.
Do not make connections to the gas regulator too tight.
Making the connections too tight may crack the regulator
and cause a gas leak. Do not allow the regulator to turn
when tightening fittings.
A
B C
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have 1/2"
[13 mm] male pipe thread)
D. Flexible connector
Complete Connection
1. Check that the gas pressure regulator shut-off valve
is in the on position.
A. Gas pressure regulator shut-off
valve shown in the on position
2. Open the manual shut-off valve in the gas supply line.
The valve is open when the handle is parallel to the gas
pipe.
A
A. Closed valve
B. Open valve
3. Test all connections by brushing on an approved
non-corrosive leak-detection solution. If bubbles appear,
a leak is indicated. Correct any leak found.
4. Remove cooktop burner caps and bases from package
containing parts.
5. Align the gas tube opening in the burner base with the
orifice holder on the cooktop and the igniter electrode
with the notch in the burner base.
D
E
H
G
F
E. Manual gas shut-off valve
F. 1/2" (13 mm) or 3/4" (19 mm)
gas pipe
G. Use pipe-joint compound.
H. Adapter
A
B