4.1.5.1- Cleaning, h
The equipment includes an automatic cleaning system, based on reversing
polarity in the electrolysis cell. These cleaning cycles are performed regularly.
The time between cleaning (in hours) can be adjusted depending on the water
hardness of your swimming pool.
It is possible to select cleaning intervals from 1 to 8 hours.
4.1.5.2 - Language
From the configuration menu select "Language", press the OK button, and once
the required language has been selected, press the OK button and EXIT.
4.1.5.3- Cover
The equipment may detect the presence of a cover on the swimming pool
(only for automatic covers). In this case, it is only necessary to place the
limit switch of the cover in the terminal block, as indicated in the section on
electrical installation.
On placing the cover, the chlorinator automatically reduces production to 20%.
This variation will be reflected in the production %, and the letter "C" will be
displayed on the right side of production in the main screen. This will indicate
that the cover is activated.
If chlorination is carried out with the cover in place, when it is
removed, the pool should not be used straightaway. It is
better to wait ½ hour for any vapours between the water and cover
to dissipate.
4.1.5.4.- Buzzer
When an alarm occurs, the unit stops its production and shows an acoustic and
visual alarm to indicate that it's necessary to correct the problem.
However, it is possible to disable the acoustic alarm selecting Buzzer = N.
The unit comes with the alarm activated by defalult (Buzzer = Y).
33 / 57
N-BSSALT V3.0