Installing and connecting the DC kit
7.3
Connecting the CA1000 Dometic roof air conditioner
➤ Remove the air outlet of the roof air conditioner ( CA1000) (fig. 1, page 3).
➤ Insert the on/off cable for CA1000 into the socket on the control board of the
roof air conditioner (fig. 2 1, page 3).
➤ Lay the on/off cable of the roof air conditioner to the ECL-103 charging current
distributor.
➤ Connect the on/off cable with connections I2 and I3 of the charging current-
distributor ( ECL-103) (fig. 3 1 and 2, page 4).
➤ Attach the air outlet of the roof air conditioner ( CA1000) (fig. 1, page 3).
➤ Run the connection cable of remote control MCR-9 to the inverter and connect
( MSI1824T).
7.4
Connecting the CA2500 Dometic roof air conditioner
➤ Remove the air outlet of the roof air conditioner ( CA2500) (fig. 4, page 4).
➤ Cut the cable loop of the CA2500 on/off cable through the middle (fig. 5 A,
page 4).
➤ Connect the control cable to the on/off cable (fig. 5 B, page 4).
➤ Lay the control cable of the roof air conditioner to the ECL-103 charging current
distributor.
➤ Connect the control cable with connections I2 and I3 of the charging current
distributor ( ECL-103) (fig. 3 1 and 2, page 4).
➤ Attach the air outlet of the roof air conditioner ( CA2500) (fig. 4, page 4).
➤ Run the connection cable of remote control MCR-9 to the inverter and connect
( MSI1824T).
16
DC-Kit5