Using the DC kit

7.10
Connecting the DC kit to the power supply
➤ Check that all the connections have been made in accordance with the
instructions.
➤ Check that the roof air conditioner is closed properly.
➤ Connect the electrical connections of the components ( ECL-103).
➤ Connect the 230 V connection on the roof air conditioner with the MSI1824T
inverter plug ( MSI1824T).
➤ Connect the positive battery cables to the batteries.
➤ Check the following are working properly:
– Check the on and off values for the charging voltage regulator
– Check the priority circuit
– Switch on the air conditioning in driving mode ( air conditioning)
– Switch on the air conditioning on mains operation
➤ Only CA1000: adapt the roof air conditioner software to AC/DC operation
( CA1000).
8
Using the DC kit
The DC-Kit5 consists of several components, each with its own installation and
operating manual. Use the installation and operating manuals for the components
and make sure you are familiar with the individual devices.
This chapter contains information on operating the overall system. This operating
manual does not replace any information contained in the installation and operating
instructions for the components.
A
NOTICE!
CA2500, B2200, B1600 Plus, HB2500, FJ1100, FJ1700,
FJ2200, FL1600, FL2200, FW3000: the inverter may be damaged.
Ensure that these models are not used in the automatic air conditioning
mode or heating modes for driving. The inverter is not designed for gen-
erating this amount of power.
20
DC-Kit5
EN