USER MENU
LOW
The following menu allows the user to adjust the percentage of pellet feed.
If the stove has functioning problems owing to the quantity of pellets, adjust pellet feeding directly from the control board.
The problems correlated to the amount of fuel can be divided into 2 categories:
NO FUEL:
the stove can never develop a suitable ame, tending to remain very low even at high power.
at minimum power the stove tends to almost switch-o taking the stove into "no pellets" alarm condition.
when the stove displays the "no pellets" alarm, there may be non-burned pellets inside the burn pot.
EXCESS FUEL:
the stove develops a very high ame even at low power.
the panoramic glass is very dirty, obscuring it almost totally.
the burn pot tends to become encrusted, blocking the holes for air intake due to the excessive pellet feed, as it is only burned partially.
The adjustment to be performed is in percentages. Therefore changing this parameter will lead to a proportional variation of all stove
feeding speeds. Feeding is from -30% to +20%.
CONTROLS PROCEDURE
Press key 6.
Proceed by pressing key 2 until USER MENU is displayed.
Con rm using key 6.
Press key 2 until "pellet" is displayed.
Use keys 4-5 to increase (4) or decrease (5) the load during the WORK stage.
Press key 1 several times to con rm and exit the menu.
V1 AIR
The menu allows the user to adjust the speed of the front fan in percentage (for envisioned models).
CONTROLS PROCEDURE
Press key 6.
Proceed by pressing key 2 until USER MENU is displayed.
Con rm using key 6.
Press key 2 until ''V1 AIR'' appears.
Use keys 4-5 to increase (4) or decrease (5).
Press key 1 several times to con rm and exit the menu.
RESET
Allows the user to reset all values modi able by the user to the default values.
CONTROLS PROCEDURE
Press key 6.
Proceed by pressing key 2 untilUSER MENU is displayed.
Con rm using key 6.
Press key 2 until reset is displayed.
Press keys 4-5 to select ON and press key 6.
"DONE" will appear on the display to con rm
ENGLISH