SERVICE
DISPLAY
ASPIRAT FAULTY
FUMES PROBE
CHAMBER PROBE
ALARM
FUMES OVERHEATING
DEPR ALARM
NO
IGNITION
BLACK OUT NO IGN.
NO PELLETS
COOLING STAND BY
AUGER CONTROL
ALARM
When this message appears, contact the authorised technician to carry out the routine cleaning of the
device.
If cleaning is not carried out, the message will be displayed at every ignition without, however, interrupting
the normal functioning of the stove.
EXPLANATION
Indicates the presence of an alarm.
Fault correlated to the ue gas
exhaust motor.
Fault correlated to the fumes probe.
Failure related to the combustion
chamber probe.
The ue gas temperature has
exceeded 310°C
The mechanical depression sensor
has tripped
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
No current during the ignition phase.
In the work phase, the t° of the ue
gases has dropped below default
parameters
Attempt to release the alarm with
stove still in cooling mode.
Anomalous functioning
of pellet feeding

ALARMS

On: indicates the presence of an alarm
O : indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing button 1 for 3 seconds only if
the fumes motor has stopped and if 15 minutes have elapsed from
when the alarm was displayed.
The restoration operations must be carried out by an authorised
technician.
The restoration operations must be carried out by an authorised
technician.
The restoration operations must be carried out by an authorised
technician.
Check pellet ow (see "Pellet feed adjustment").
Check that the machine is clean, including the fumes passage.
Do not rest cloths on the machine.
Other restoration operations must be carried out by an authorised
technician.
Check closure of the door and pellet tank.
Check air vent.
Contact after-sales centre.
Check for the presence of pellets in the feed-box.
Adjust pellet ow (see "Pellet feed adjustment").
Check the procedures described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
Take the stove to OFF conditions using key 1 and repeat the
procedure described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
Check for the presence of pellets in the feed-box.
Regulate the pellet ow.
Other restoration operations must be carried out by an authorised
technician.
Every time the stove displays one of the alarms listed above it will
switch-o automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and ATTE alternately on the display. The
alarm can be reset by pressing button 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have elapsed from
when the alarm was displayed.
Contact after-sales assistance
ENGLISH
SOLUTION
57