sYMbols on tester:
Warning. Risk of electric shock.
Risk of danger. Important information. It is important that users of this
tester read, understand, and follow all warnings, cautions, safety information,
and instructions in this manual before operating or servicing this tester. Failure
to follow instructions could result in death or serious injury.
Double Insulated.
operatinG instructions:
turn unit on:
Press the power button on the end-cap for 1 second. Listen for single-beep
sound and watch for a steady green LED to illuminate in the tip of the tester.
Release the power button; the tester is now activated and is operational.
Test on known live circuit to verify tester functionality.
turn unit off:
Press and hold the power button on the end-cap for ½ second. Listen for a
double-beep sound and watch the "power on" green LED turn off. Release the
power button; the tester is now deactivated and is not operational.
system self-test:
The "power on" green LED visually confirms battery sufficiency, system
integrity, and operation/active mode. Always test on known live circuit to verify
tester functionality prior to use.
checking for the presence of ac voltage:
Prior to use, test on known live circuit to verify tester functionality.
Place tip of the tester near an AC voltage. If the tester detects voltage, the
"power on" LED in the tip of the tester changes color from green to red and a
continual beeping sound is generated.
low battery indication:
Scenario 1 – Powering on the tester: The "power on" LED in the tip of the tester
changes from a steady green to a blinking green and a series of beeping sounds
is generated. The tester then turns off. The unit is now deactivated and is not
operational; the batteries require replacement. To replace the tester batteries
refer to the Maintenance section titled "Battery Replacement."
Scenario 2 – Operating the tester: If the LED lights dim and the tone fades, the
tester may require new batteries. To replace the tester batteries refer to the
Maintenance section titled "Battery Replacement."
auto power off:
After 4 minutes of non-use, the tester automatically powers off to conserve
battery life. Listen for a double-beep sound and watch the "power on" green
LED turn off. The tester is now deactivated and is not operational.
Maintenance:
battery replacement:
•
Orient the tool/tester with the pocket-clip facing you.
•
Gently depress the tab, Fig. 2, until you can slide the end-cap off the main
body of the tester.
•
Remove the batteries using caution to prevent damage or injury to the
internal components.
•
Replace with two
alkaline AAA 1.5 volt or IEC LR03 or NEDA 24A batteries.
•
Place batteries into tester with the positive terminals facing the tip, Fig. 3.
•
Carefully align and slide the end-cap to the body of the tester, Fig. 4. Push
the cap until it is fully seated (denoted by a clicking sound), Fig. 4.
•
note:
Hold pocket-clip on cap close to tester body while sliding cap onto
tester.
•
Test on known live circuit to verify tester functionality.
cleaning tester:
•
Tester contains sensitive electronic components; do not submerse in liquid.
•
Do not use alcohol, ammonia or cleaners containing solvents to clean tester.
•
Gently wipe the tester with Klein Kleaners
cloth or a cloth containing a mild cleaning solution.
•
Make sure the tester is completely dry prior to operation.
disposal:
•
Do not throw depleted batteries away; please recycle properly.
•
Do not throw tester away, please recycle properly.
•
Please see www.epa.gov or www.erecycle.org for additional information.
(CAT. # 51425 or 51426), a damp
®
WarrantY
Klein electronic test and measurement devices (and accessories),
manufactured and sold for commercial or industrial uses, are war-
ranted to be free from defects in materials and workmanship for
two years from the date of purchase (unless otherwise noted on the
product packaging). THERE ARE NO IMPLIED WARRANTIES OF MER-
CHANTIBILITY OR FITNESS. At its option, Klein will repair or replace,
or refund the purchase price of, any product which fails to conform to
this warranty under normal use and service. in no event shall Klein
be liable for incidental or consequential damage. This warranty does
not apply to batteries.
Fig. 2
AAA
AAA
Gently push down on locking tab.
While pushing down on tab, slide cap off body.
Fig. 3
AAA
AAA
AAA
align locking tab with cap.
Fig. 4
slide cap onto body.
align channel tabs on cap with slots on tester
body (one on each side of tester).
AAA
Hold pocket-clip on cap
close to tester body while
sliding cap onto tester.