PLEASE NOTE: the information in the table below and the action to take is intended for the use of
the assistance centre personnel and others qualified to install/maintain the equipment.
Error message
The data and features referred to are not binding on EFFEGIBI and the company reserves the right to make any appropriate changes
OPERATING AND MAINTENANCE MANUAL
FOR NUVOLA SMART POWER
Meaning
Control panel fault
Control pa-
shown
nel function
fault
No system dialogue
Lack of
with an element
communica-
already recognised
tion with 1 or
more devices
The control panel
Lack of
is not in dialogue
communica-
with the other
tion with 1 or
elements of the
more devices
system.
Generic generator
Internal error
circuit board error.
in the gene-
This may mean:
rator circuit
- generator over-
board.
heating;
- low power volta-
ge;
- heating element
broken.
Temperature probe
error
Boiler
water-level
Boiler water-
still high
level
been high for
too long
Boiler
water-
Boiler water-
level not yet high
level not rea-
enough
ched in the
p e r m i t t e d
time
without having to give prior notice or replace this manual.
Error
Cause
Control panel
1. Disconnect the product
fault
from the electric power
2. After a few seconds power
up again
3. If the error persists, con-
tact the service centre.
One of the de-
1. Check the device connec-
vices is not re-
tions.
ceiving power
2. If the error persists, con-
or is not con-
tact the service centre.
nected.
One of the de-
1. Check the device connec-
vices is not re-
tions.
ceiving power
2. If the error persists, con-
or is not con-
tact the service centre.
nected.
Others
Contact the service centre
Problem with
Contact the service centre
the panel tem-
perature pro-
be.
Outlet
valve
1. Check that the outlet path
had
not working.
is clear.
2. Check that the steam pipe
is not obstructed, bent or is
not siphoning.
3. Clean the outlet valve.
Lack of water
1. Check that the water tap is
in the system
turned on.
or
the
inlet
2. Check that there is water
valve filter is
in the system.
blocked.
3. Check that the filter at the
entrance to the inlet valve is
not blocked.
EN
Solution
Error pri-
ority
TOP
HIGH
HIGH
- Overhea-
ting
(MEDIUM)
- Low po-
wer voltage
(MEDIUM)
-
Heating
e l e m e n t
b r o k e n
(low)
HIGH
LOW
LOW
27