DISPLAY SIGNAL AND ERROR TABLE
During normal mode, some errors could occur that are described in table 2� The error
code is shown on the display� Some errors prevent some machine automatisms from being
used (i�e� errors E00 and E01) or cause them to stop early (i�e� error E11)�
Pressing the Clear key on the control panel cancels the error code on the display but if
the cause of the error is not removed and the command that generated it is repeated,
the message will reappear
ERROR #
MEANING
E00
No calibration data
E01
No signal on analogue channel
#1 (radial movement measure-
ment potentiometer)�
E02
No signal on analogue channel
#2 (channel currently not used)
E03
No signal on analogue channel
#3 (channel currently not used)
E04
No signal on analogue channel
#4 (analogue laser for the Side
To Side)
Operator's manual MONSTER AGTT
Flashes
On
upon arrival
steady if the
of the com-
cable
mands
is con-
nected;
otherwise off
Flashes
On
upon arrival
steady if
of the
the cable
commands
is con-
nected;
otherwise
off
Variable
Technical
messages
service
personnel
Variable
Factory
messages
personnel
ACTION
Calibrate the machine� If
the error remains replace the
board CPU-RX2�
This signal appears also
when a new board is
installed�
Check the connection of the
potentiometer and its condition�
If the error persists contact
technical assistance�
Check the connection of the
laser and its condition� Check
that the glass on the front of
the laser is not dirty� If the error
persists contact technical
assistance�
This operating
mode includes the
global correction
Setting and Calibra-
tion programmes�
UK