6 - INCONVENIENCES AND POSSIbLE REMEDIES
MALFUNCTION
•
The conditioner does not work.
•
The conditioner works only for a
short period.
•
The conditioner works but does not
refresh the room.
•
Water leaks from the conditioner
during transport.
•
Alarm signal " Fi " appears on the control
panel display
•
The conditioner switches off, the controls
on the remote control and the control
panel do not respond and alarm signal
"2" flashes on the control panel display.
•
The conditioner switches off, the controls
on the remote control and the control
panel do not respond and alarm signal
"8" flashes on the control panel display.
•
The air conditioner is off, the number "3"
flashes on the control panel display and
the red led is on.
•
In cooling, night-time or automatic mode,
minimum speed cannot be selected.
•
In heating mode ( HP only) the air con-
ditioner stops the compressor or the
external fan cyclically for a few minutes.
Do not try to repair the appliance by yourself.
If the problem has not been solved, please contact your local retailer or the closest assistance service.
Supply detailed information about the malfunction and the equipment version.
EN - 34
CAUSE
•
No power.
•
The plug has not been inserted.
•
The power switch is set to "0"
•
Timer is ON
•
The temperature set is too close to
ambient temperature.
•
Suction of outside air is obstructed.
•
Window open.
•
Some source of heat is operating in the
room (burner, lamps, etc.) or the room
is crowded.
•
The temperature set is too high.
•
The power of the conditioner is not
suitable for ambient conditions or
dimensions.
•
The conditioner has been tilted or laid
flat.
•
The filter is dirty
•
Room temperature sensor
•
Evaporating fan motor
•
Excessive accumulation of water inside
air conditioner
•
Ambient temperature too low
•
Ambient temperature too low or too high
WHAT DO I DO?
•
Wait.
•
Plug in the conditioner.
•
Set the power switch to "I"
•
Switch off the timer
•
Lower the temperature set.
•
Remove the obstructions.
•
Call the Service Center.
•
Close the window.
•
Eliminate sources of heat.
•
Lower the temperature set.
•
Remove the plug (24) and drain the
water before moving the conditioner.
•
Clean the filter
•
Switch the appliance back on and
press button SW7 on the control panel
for 5 seconds so that the alarm signal
disappears from the display.
•
Call the Service Centre.
•
Call the Service Centre.
•
Drain the water by removing the cap
(24). Contact the service centre if this
alarm occurs too frequently.
HP: this alarm is normal when heating
without a water drain pipe installed.
•
Air conditioner behaviour is normal.
•
Air conditioner behaviour is normal.