INSPECTION AND MAINTENANCE
colorless and odorless gas which can be
fatal if inhaled for any length of time.
ENOW00036-A
When the engine is started in the test tank,
to avoid over heating and water pump
damage, be sure the water level is at least
10 cm (4 in.) above the anti ventilation
plate.
And be sure to remove the propeller, when
starting the engine in the test tank. (See
page 78)
Run the engine only at idling.
3
2
1. Test tank
2. Water
3. Over 10 cm (4 in.)
10
ENOM00950-0

Fuse replacement

ENOW00923-0
Before replacing a fuse, disconnect the
battery cable from the battery negative (-)
terminal. Failure to do so may cause a
short-circuit.
ENOW00924-0
Never use a fuse with a rating that exceeds
the specified rating as this could cause
serious damage to the electrical system.
CAUTION
1
ENOF00863-0
CAUTION
CAUTION
If a blown fuse is detected, try to deter-
mine the cause for this and correct it. If the
cause for the problem is not corrected, the
fuse will likely blow again.
If the fuse continues to blow, request an
authorized Tohatsu dealer to inspect the
outboard motor.
1. Stop the engine and disconnect the
battery cable from the battery negative
(-) terminal.
2. Remove the engine cover.
3. Remove the fuse box lid.
4. Remove the fuse and check it. If the
fuse is blown, replace it with a fuse of
the same specified rating. The out-
board motor is supplied with spare
fuses in the spare fuse holder.
60/70
1
1. Blown fuse
ENOF02364-0