Telcoma STEALTH Instrucciones De Uso página 45

Motorreductores 24v con brazo articulado para puertas batientes
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Term. n.
1 (L)
230V
2 (GND)
3 (N)
3 (+)
CB24
4 (-)
BSC
6 (com)
7
8K2*
BSA
6 (com)
8
8K2*
FT1
6 (com)
9
FT2
6 (com)
10
STP
6 (com)
11
PED
6 (com)
12
P/P
6 (com)
13
14
M1
15
16
M2
17
18 (no)
US1
19 (nc)
20 (c)
12V
21 (+)
22 (-)
23 (+)
24 (-)
24V
25 (+)
26 (-)
27 Braid
28 Control
Function / Device
Power supply
Input for battery charger and
batteries (optional)
Sensitive edge input
tripping during CLOSING
Sensitive edge input
tripping during OPENING
Photocell contact input
Photocell contact input
STOP command input
PEDESTRIAN command input
STEP/STEP command input
24V output motor M1
24V output motor M2
Input with selectable function
Electric lock
Flasher output
Auxiliary device power supply
output
Radio antenna input
V/I max
/
230/2A
/
Connect to 230 V line.
Electric connections fig. O,
24dc
/
Make sure the polarity is correct
Input enabled during closing. Connect 8K2 edges or an NC
contact with 8K2 resistance in series (Fig. N).
8K2/NC
/
If not used (terminal free), set dip-switch 1 of item 7(fig.L) to
ON
Input enabled during opening. Connect 8K2 edges or an NC
8K2/NC
/
contact with 8K2 resistance in series (fig. N).
If not used (terminal free), set dip-switch 2 of item 7 (fig.L).
Reverses direction during closure.
NC
/
If not used, set dip-switch 3 of item 7 (fig. L) to ON
Temporary block of manoeuvre during opening phase
NC
/
Reverses direction during closure.
If not used, set dip-switch 4 of item 7
Blocks all functions.
NC
/
If not used, set dip-switch 5 of item 7
in 2 motor mode, only M1opens.
in 1 motor mode, the gate partly opens for a
NA
/
programmable time (see "programming pedestrian
opening").
See settings of dip-switches 1 and 2 of item 10 (fig.
NA
/
L)
In 2 motor configuration, M1 is first to open and
24dc
/
second to close. M1 controls the leaf with electric
lock if installed
In 2 motor configuration, M2 is first to open and
24dc
/
second to close.
/
See settings of dip-switche 7 of item 10 (fig. L)
/
12dc/1,5A
/
Active for a few seconds at everystart of opening
24dc/1A
/
Switches on with motor in motion.
24dc/1A
/
Make sure the polarity is correct
Connection only necessary with receiver OC2 active.
/
Use aerials for frequency 433 MHz (50 Ohm)
GB
Notes
(fig. L)
to ON
(fig. L)
to ON
44

Publicidad

Tabla de contenido
loading

Tabla de contenido