characteristic table:
By
pass
Burner
1/100
mm
L.P.
44
Gas
Oven
Natural
44
Gas
Rated supply pressure
(*)
= At 15 °C and 1013,25 mbar - dry gas with greater calorific power
electrical connection
The appliances are provided with a three-pole feeding cable and
work with alternate current and single-phase voltage indicated on
the "Rating plate of the product" report at the end of the instruction
manual and on the product. The grounding conductor of the cable is
marked with the colours yellow/green.
connection of the feeding cable to the mains
Connect the feeding cable of the oven to a plug suitable for the load
indicated on the "rating plate of the product".
· In case of a direct connection to the mains
(cable without plug), it is necessary to insert
a suitable omnipolar switch before the appli
ance, with minimum opening between con
tacts of 3 mm (the grounding wire should not
be interrupted by the switch).
Before connecting to the mains, make sure
that:
· The electrical counter, the safety valve, the
feeding line and the socket are adequate
towithstand the maximum load required (see
rating plate).
Thermal power (*)
(kJ/h)
Output
Rated
Reduced
G30 -G31
5400
164 - 161
2880
7000
LP gas
Natural gas
Injector
Output
(g/h)
1/100mm
(l/h)
G20
75
214
2,74 kPa
1,76 kPa
-
-
Injector
1/100mm
110
34