FASTENER APPLICATION CHART
FASTENER
APPLICATION
2" 15-1/2 Ga Staple
• Angle staple onto 5/8" - 3/4"
underlayment over joist construction
• Surface (face) nail onto 5/8"- 3/4"
underlayment over joist construction
1-1/2" 15-1/2 Ga Staple • Angle staple onto 5/8" - 3/4"
underlayment over concrete slab or
hydronic coil heating systems
• Surface (face) nail onto 3/4"
underlayment over concrete slab or
hydronic coil heating systems
ACCESSORIES
WARNING
Accessories other than those shown below could lead to malfunctioning which results in injuries.
STANDARD ACCESSORIES
1 . Mallet
2 . Wrench Set (Service Parts Kit)
3 . Pneumatic Tool Lubricant
4 . Safety Goggles
5 . Reversible Shoe Base
6 . Swivel Air Inlet Connector
7 . Carrying Case
AVAILABLE STAPLES
47271: 1-1/2" Crown Staples, 15½ Ga, BCS Type (1000/pk)
47261: 2" Crown Staples, 15½ Ga, BCS Type (1000/pk)
4723: 2" Crown Staples, 15½ Ga, BCS Type (7700/pk)
Note:
Accessories are subject to change without any obligation on the part of PORTA-NAILS.
T&G FLOORING THICKNESS
• 3/8", 1/2", 9/16", 5/8",
3/4", 33/32"
• 3/4", 33/32"
• 5/8" - 33/32"
OPTIONAL ACCESSORIES
1 . 9/16" - 3/4" Pre-finished (wide profile)
Flooring Shoe ( Code No . 47395)
2 . Floor tightening and straightening jack
(Code No . 47100)
10
APPLICATIONS
For installation of 1/2", 5/8" and 3/4" tongue and groove solid wood and engineered
hardwood flooring .
BEFORE OPERATION
Read over section titled "SAFETY" ( pages 4 - 7 )
Make sure of the following before operation.
WORKING ENVIRONMENT
WARNING
• No flammable gas, liquid or other flammable objects at worksite,
• Clear the area of children or unauthorized personnel.
AIR SUPPLY
DANGER
WARNING
• Never connect tool to pressure which potentially exceeds 200 psi (13.7 bar 14 kgf/cm
• Never use non relieving coupler on tool.
1. Power Source
• Use only clean, dry, regulated compressed air as a power source for this tool
• Air compressors used to supply compressed air to this tool must comply with the
requirements of the latest version of ANSI Standard B 19 .3 "Safety Standard For
Compressors For Process Industries ."
• Moisture or oil in the air compressor may accelerate wear and corrosion in the tool. Drain daily.
• Air volume is as important as air pressure. The air volume supplied to the tool may be
inadequate because of undersized fittings and hoses or from the effects of dirt and water in
the system . Restricted air flow will prevent the tool from receiving an adequate volume of air,
even though the pressure reading is high . The results will be slow operation, jamming, miss-
feeds or reduced driving power . Before evaluating tool problems for these symptoms, trace the
air supply from the tool to the supply source for restrictive connectors, swivel fittings, low
points containing water and anything else that would prevent full volume flow of air to the tool .
2. Filter-Regulator-Lubricator
• A pressure regulator with an operating pressure of 0-125 psi (0-8.6 bar 0-8.8 kgf/cm
control the operating pressure for safe operation of this tool . Do not connect this tool to air pressure
which can potentially exceed 200 psi as tool may fracture or burst, possibly causing injury
• Filter-Regulator-Lubricator units supply an optimum condition for the tool and extend the tool life.
• NEVER use oxygen or other bottled gases.
Explosion may occur.
).
2
) is required to
2
11