1.1 Permissible operating conditions / measuring range
Operating conditions
Temperature sensor
Flow sensor
Temperature spread
Measuring rate Flow
Measuring rate Temperature
Climatic conditions
The installation must be performed in a non-condensing environment as
well as in closed spaces (indoor installation). The ambient temperature
must be between 5...55 °C.
Temperatures >35°C have a positive effect on battery lifetime.
2.
Transport and storage
Unpacking
Energy meter are measuring devices and must be handled with care. To
protect against damage and soiling, they should only be unpacked imme-
diately prior to installation.
Transport
The transport of the meter is permitted only in the original package.
Storage
The meter may only be installed in dry areas.
Typical storage temperature +5 °C ... 55 °C
Maximum storage temperature -20 °C ... 60 °C (dry, duration up to
4 weeks)
relative humid environment <93%