Error
Description
code
C - 1
Basic parameter error in flash or RAM - Meter must be
replaced
E - 1
Erroneous temperature measurement
Temperature range exceeds [-9.9 °C...190 °C]
Sensor short circuit
Sensor break
E - 3
Temperature sensor mixed up in hot and cold line
E - 4
Hardware error during ultrasonic measuring
Ultrasonic transducer defective
Short-circuit ultrasonic transducer
E - 5
too frequent reading
no M-Bus communication possible for a short time
E - 6
flow direction incorrect
Installation of flow sensor wrong
E - 7
No reasonable ultrasonic receive signal
Air in the measuring path
E - 9
Warning: Running out of battery capacity
7.
Maintenance
Flow sensor and temperature sensor may not be connected from
the integrator.
After repair work, perform recalibration in an accredited testing
agency.
Information concerning reconditioning or maintenance can be
found in the processing concept (this will be made available for
laboratories and testing agencies upon request).