Electrical - Flotec FP0F360AC Manual Del Usuario

Ocultar thumbs Ver también para FP0F360AC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical

Disconnect power before working on pump, motor, pressure switch, or wiring.
Motor Switch Settings
NOTE: 1/2 HP motors are wired for 115 volts only, and have no motor wiring to change.
Your motor terminal board (located under the motor end cover) should look like one of those below.
If the motor can operate at either 115 or 230 volts, it is set at the factory to 230 volts. Do not change motor wiring if
line voltage is 230 volts, or if you have a single voltage motor.
Never wire a 115 volt motor to a 230 volt line.
Plug Type Voltage Selector
Voltage Change Plug
Ground Wire Connection
Figure 9: Voltage set to 230 volts, Plug Type
Voltage is factory set to 230 volts. To change to 115 volts:
1. Make sure power is off.
2. Pull the voltage change plug off of the tabs.
3. Move the voltage change plug to the 115 volt posi-
tion. The plug will now cover 2 metal tabs and the
arrow on the plug will line up with the 115V arrow on
the label (see Figure 10).
Figure 10: Voltage set to 115 volts, Plug Type
4. Attach the incoming power leads to the two outer
screws on the pressure switch as shown in Figure 9.
5. Attach the ground wire to one of the grounding
connections, shown in Figure 9.
6. If there are other wires, they should be capped.
7. Reinstall the Motor end cover.
For parts or assistance, call Flotec Customer Service at
Power Connections
Pressure Switch
Dial Type Voltage Selector
Power Supply Connections
Voltage
Change
Dial
Ground Wire Connection
Figure 11: Voltage set to 230 volts, Dial Type
Voltage is factory set to 230 volts. To change to 115 volts:
1. Make sure power is off.
2. Turn the dial counter-clockwise until 115 shows in the
dial window as shown in Figure 12.
Figure 12: Voltage set to 115 volts, Dial Type
3. Attach the incoming power leads to the two outer
screws on the pressure switch as shown in Figure 11.
4. Attach the ground wire to the grounding connections
as shown in Figure 11.
5. If there are other wires, they should be capped.
6. Reinstall the Motor end cover.
1-800-365-6832