SLV Elektronik GmbH
ENGLISH
INSTRUCTION MANUAL FOR
WALL FITTING
OUT BEAM G 8,5 / R7s
1.
NOTES ON SAFETY
Installation, mounting or works on the electrical connection may
only be carried out by an approved electrician.
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no
decoration.
Keep children away from the product.
The fixture may only be operated with a complete and intact
protection glass.
Operate the product only when it functions properly:
In case of a malfunction you may NOT touch the product or operate it
further. Disconnect the product from the power supply by an external
switch or by the fuse.
If touched or further operated there is danger from electric shock,
burning, or fire.
A malfunction exists when:
visible damages appear.
the product does not work properly (e.g. flickering).
smoke, steam or crackling sounds appear.
smell of burning is recognisable.
an overheating is recognisable (e.g. by discolouration of adjacent
surfaces).
Operate the product only after maintenance and examination by an
approved electrician!
2.
USE AS DIRECTED
This product serves exclusively lighting purposes and may:
only be used with a voltage of 230V ~50Hz.
only be operated when firmly mounted.
not be exposed to strong mechanical loads or to strong
contamination.
only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
not be modified or converted.
3.
OPERATION
Exchange the light source always before it reaches its lifespan, to avoid
personal injuries, or damages of the fixture or other objects.
Disconnect the product from the power supply, before you exchange
the bulbs. Let the light source cool down before replacement.
There exists danger of burning!
Use only light sources that are approved for the product. Approved light
sources are indicated on the type label.
Other types of light sources may cause fire risk, damage the product
or lead to malfunction.
Replacing the light source: see Installation.
Use a piece of fabric to insert the bulbs - do not touch them with bare
fingers. Carefully remove any fingerprints from the bulbs.
Check and clean the gasket after each opening of the fixture. The
bearing surface of the gasket must be free of dirt. These measures
ensure that the IP class is maintained.
Note the proper fit for the gasket. Tighten the screws in a cross-wise
order, to achieve an even pressure on the gasket.
HIT: It takes about five minutes until the lamp reaches its full potential.
After switching it off, wait 5 to 10 minutes to let the light source cool
down before restarting it.
4.
MAINTANANCE AND CARE
The following enviromental influences may have unwanted effects on
the surface of the product:
acid rain and sour soil
high salt content in the air
thawing salt
cleaning agents
fertilizer especially in flowerbeds
other chemical substances (e.g. herbicides)
Protect the product by adequate means to avoid unwanted changes of the
surface.
Disconnect the product from the power supply and let it cool down,
before you clean the product.
If disregarded there may be danger of electric shock or by burning
when cleaning the product.
Cleaning: Clean the product on a regular basis using a slightly
moistened, soft and fluff-free cloth. Please also note additional supplied
notes on maintanance and care.
5.
ADDITIONAL IMPORTANT NOTES
Storage: The product must be stored in a dry and clean environment. Do
not strain the product mechanically during storage.
Warranty: In case of a warranty contact your dealer.
Disposal: Notes on the correct disposal in Germany are found on
www.slv.de.
6.
INSTALLATION
(only by an approved electrician)
Switch off the mains or respectively the connection lead before doing
.
any works
There exists mortal danger from an electric shock.
Use only parts, which are supplied with the product or are described as
accessories!
Otherwise the product or the whole installation may not be secure.
Danger for life or danger of fire may exist!
Inspect the product for loose parts inside the housing. When there are
loose parts inside the housing and these are not explicitly described the
product may not be installed or operated.
The housing maybe voltage-carrying. Danger of electric shock!
Use the supplied fastening material only when it is suited for the
installation background. If this is not the case use only fastening material
suiting the installation background.
When using fastening material that is not suitable there may be
danger from falling objects.
Unpacking
Consignment:
Three protective tubes
Fastening materials
Carefully take the product out of the packaging removing any transport
safeguards.
Before disposal of the packaging material make sure that all
components of the product are removed.
Installation place
The product is solely suited for installation on a wall.
Make sure that the product is mounted on a stable, even and tilt-fixed
background.
The light exit should be placed at least so far from the illuminated
surface, as indicated as minimum distance on the type plate of the
luminaire:
. Pay special caution to easily inflammable objects
(e.g. foliage).
Separate Installation Steps
Notice: Do not try to seal the product yourself, using additional silicon or
another sealant.
Remove the fitting housing from the mounting plate by loosening the
screws.
Determine the place of installation and mark the holes to be drilled. Note
that the cable outlet of the mains supply corresponds with the cable inlet
of the fixture. Do not damage the power supply line, e.g. by drilling,
screws or strong bending.
Direct the connection lead through the rubber gasket into the fitting.
Fasten the mounting plate to the mounting surface. Equip the screws
with the supplied sealing rings.
Electrical Connection
The product must be able to be separated by an all pole separation
from the current supply.
Equip the three wire ends with protective tubes.
For electric connection attach the black or brown wire (live conductor)
of the mains supply with the clamp L and the blue wire (neutral
conductor) of the mains supply with the clamp N. The green-yellow
wire (protective conductor) of the mains supply has to be tightly
screwed into the earth clamp
of the product.
Plug the earth conductor of the housing back on the earth clamp.
Inserting the light source: Use a piece of fabric to insert the bulbs - do
not touch them with bare fingers. Carefully remove any fingerprints from
the bulbs.
HIT: Stick the bulb into the socket.
R7s: Direct the bulb, slightly tilted, into the socket. Let both sides lock
in. In case the light beam is not exactly vertical, you may carefully
bend the socket holder in order to achieve a vertical light beam.
Note the proper fit for the gasket. Tighten the screws in a cross-wise
order, to achieve an even pressure on the gasket.
Now fasten the fitting back to the mounting plate. Do not forget to
apply the sealing rings!
Check if the product functions properly and is securely fixed.
The product is now ready for operation.
art.-no. 227015/20/23/24
©
SLV Elektronik GmbH, Daimlerstr. 21-23, 52531 Übach-
03/2009
Palenberg, Germany, Tel. +49 (0)2451 4833-0
Technical Details are subject to change.