Wearing Parts - Oase Filtral UVC 700 Instrucciones De Uso

Ocultar thumbs Ver también para Filtral UVC 700:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the unit immersed in water or filled with water in a frost-free place. Do not flood the power plug!

Wearing parts

The UVC lamp, the different filters and the rotor are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
Malfunctions
Malfunction
The unit is not operating
Delivery or fountain height insufficient or not
consistent,
Cloudy water
UVC lamp does not light up
Unit switches off after a short running period
Cause
No mains voltage
Flow regulator excessively throttled
Nozzle blocked
Excessive pressure losses in the hoses
Intake openings blocked
Filters clogged
Rotor blocked
Pond extremely dirty
Quartz glass tube soiled
Lamp overheated. The temperature switch has
switched off the lamp
UVC lamp defective
UVC lamp is not correctly seated in the socket
Water temperature too high
- English -
Remedy
Check mains voltage
Set flow regulator
Unscrew and clean the nozzle insert
Reduce hose length and connecting parts to a
minimum, route hoses as straight as possible
Clean housing
Clean filters
Clean rotor
Remove algae and leaves from the pond,
change the water
Remove UVC clarifying unit and clean the
quartz glass tube
The lamp will automatically switch on again
once cooled down
Replace the UVC lamp
Correctly insert the UVC lamp into the socket
Note maximum water temperature of +35°