Fig. 2: Attachment point
5.3
Storage
Installation and operating instructions Wilo-Rexa PRO
Transport and storage
CAUTION
Wet packaging can tear!
The product may fall on the ground if unprotected and may be damaged. Lift wet pack-
aging carefully and replace it immediately!
To protect the pump from damage during transport, only remove the outer packaging at the
operation site. Pack used pumps for shipping in tear-proof plastic bags of sufficient size so
that they are leakproof.
Furthermore, observe the following points:
▪ Adhere to national safety regulations.
▪ Use legally specified and permitted lifting gear.
▪ Select lifting gear according to the present conditions (weather, attachment point, load
etc.).
▪ Only attach lifting gear to attachment points. The fixation must be made with a shackle.
▪ Use lifting equipment with sufficient bearing capacity.
▪ The standard safety of the lifting equipment must be guaranteed during application.
▪ When using lifting equipment, get a second person to coordinate the procedure if necessary
(e.g. view blocked).
DANGER
Danger due to fluids which are hazardous to health!
When the pump is used in fluids which are hazardous to health, decontaminate the pump
after removal and before all work! There is a risk of fatal injury! Observe information from
the work regulations! The operator must ensure that the personnel have received and
read the work regulations!
WARNING
Sharp edges on the impeller and suction port!
Sharp edges can form on the impeller and suction port. There is a danger of limbs being
severed! Protective gloves must be worn against cutting injuries.
CAUTION
Total loss due to moisture penetration
Moisture penetration in the power supply cable damages the power supply cable and the
pump! Never immerse the end of the power supply cable in a liquid and tightly seal during
storage.
Newly delivered pumps can be stored for a year. Regarding storage for more than one year
contact customer service.
Observe the following points regarding storage:
en-US