Descargar Imprimir esta página

Important; Safety Devices; Gb Instructions For Plasma Cutter - ELLETRO PLASMA Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18

Important

Before using this device all people authorised to its use, repair or
inspection, should read the book "Safety rules for using
machines" and the "Instruction manual" specific for every
machine. Contact your distributor if you have not understood
some instructions.

1 SAFETY DEVICES

This unit is provided with the following safety devices :
Thermal:
located on the power transformer windings to avoid
overloads and signalled by indicator light C on (see picture 1).
Pneumatic: located on the torch feed line to avoid insufficient
air pressure and signalled by indicator light P (see picture 1).
Electric:
1) located on torch body to avoid dangerous voltages while
replacing nozzle, diffuser, electrode or nozzle holder.
2) to stop the unit when the electrode is so worn that it is
required to be replaced. This second function is signalled by
indicator light P (picture 1).
3) located on the panel of the machine to avoid dangerous
tensions on the torch while replacing it.
Do not remove or short-circuit the unit safety devices.
Only use original spares.
Always replace any damaged part of the unit or torch with
original material.
Do not use any torches other than the original one.
Do not let the unit work without covers. This would be
dangerous
for
operator
surrounding the work area and would prevent the unit
from cooling efficiently.
2 DESCRIPTION OF TECHNICAL SPECIFICATIONS
IEC 974-1 ................ This machine is
EN60947-1
manufactured according to
these international standards.
Art. .......................... Article number with serial
number must appear on any
requests concerning the machine.
......... Transformer-rectifier three-phase.
INSTRUCTIONS FOR PLASMA CUTTER
and
for
those
who
......................... Drooping characteristic.
.............. Plasma arc cutting.
Uo ........................... Secondary no-load voltage.
X ............................. Duty-factor percentage.
I
.............................. Cutting current.
2
U
............................. Secondary voltage with cutting
2
U
............................. Nominal supply voltage.
1
3~50/60Hz
I
............................... Absorbed current at the
1
IP23 ........................ Grade of protection of frame.
....................... Fit to work in high-risk areas.
NOTES: In addition, the cutting machine has been designed to
work in areas with grade 3 of pollution(See IEC 664).
3 DESCRIPTION OF UNIT DEVICES (see picture 1 and 2)
are
A)
Mains switch.
B)
Mains pilot light.
C)
Light signalling thermostat.
D)
Gauge.
E)
Light signalling air pressure is not enough.
G)
Texas connection.
H)
Cutting power adjusting knob.
I)
Air pressure reducing unit.
L)
Feed cable.
M)
Cable pressing device.
P)
Light signalling electrode is worn out.
R)
Torch fixed adapter.
S)
Pressure switch socket.
T)
fan
U)
Light signalling danger of overvoltage.
3.1 ASSEMBLY AND ARRANGEMENT (see picture 3)
Unpack the unit and assemble the handle with the supplied
spanner. Place the unit in properly ventilated if possible not
dusty room making sure that the air inlet and outlet from
cooling slots are not obstructed. Fit torch on the unit Fig. 3 as
follows:
1) Unscrew the screws M6X16 on the front panel. Slip the
flange (1) on the torch (2) and screw the torch in the adapter
(3). Insert the flange positioning the insert with the spring in
the corresponding hole on the panel of the machine. Block the
flange with the screws M6X16 in the holes with the thread
inserts.
2) For the replacement of the torch, unscrew the screw
M6X16, take away the flange (1) and unscrew the torch (2)
from the adapter (3). For the assemblage of the new torch
follow the instructions at the point 1. Pay particular attention
not to dent the power pin and not to bend the adapter pins; a
The
duty-factor
expresses
percentage of 10 minutes in which the
Plasma can operate at a determined
current, without over heating.
current I
.
2
Three-phase supply 50 or 60Hz.
corresponding cutting current I
Grade 3 as a second number
means that this unit is fit to
work outside under the rain.
the
.
2
6

Publicidad

loading