Set-Up And Start-Up (A); Adjusting The Light Cone; Replacing The Glass Or Coloured Glass And The Bulb (B) - Oase Lunaqua 3 Solo Instrucciones De Uso

Ocultar thumbs Ver también para Lunaqua 3 Solo:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
- EN -

Set-up and start-up (A)

The unit is supplied completely fitted, including a 20 W bulb. Connection of the electrical cable is reserved for a quali-
fied electrician. As standard, the spot light is supplied (completely assembled) with 2 blind plugs. The scope of delivery
includes 2 sets of seals each for HO5RN-F 2 x 1.0 mm
be able to install the connection cable (A1). If you wish to connect several spot lights, remove both cable lead throughs
to be able to loop the connection cable (A1). Open the connection housing (A2). Push the union nut on the cable first,
followed by the sealing insert (A3). Strip the connection cable and terminate the wires with ferrules (A3). Wire the spot
light as shown in figure A4. If you wish to connect more than one spot light, wire as shown in figure A5 to be able to
loop all lights. Firmly screw-connect the cable lead throughs by means of union units. Ensure that the outer jacket of
the connection cable protrudes at least 5 mm from the rubber sealing (A4, A5). Place the cover with both O rings onto
the connection housing and tighten firmly (A6).
Only use a safety transformer (alternating voltage power pack) according to VDE 0570, IEC 61558, EN 61558
Attention:
to operate the spot light.
If operated above water level, keep a safety distance from combustible materials of at least 50 cm. Do not
Danger of fire:
cover the unit. Ensure a safe seating.
Bolt the mounting plate to the spot light with a screw connection and use it to slide the spot light onto the ground stake
or onto the spot light holder of an OASE water feature pump (A7). Ensure that the nut is in the small hole and the
screw in the large hole of the screw connection (A7). Position the unit such that it does not present a hazard for any-
body. Check the spotlight function.

Adjusting the light cone

Attention! Never loosen the union nut! Water might enter the spotlight.
The light angle can be infinitely adjusted from 10° to 40° by turning the focussing ring (A8).

Replacing the glass or coloured glass and the bulb (B)

Adhere to the safety instructions! Disconnect the power! Undo the screw connections at the mounting plate and re-
move residual water. Ensure that no moisture can enter the unit. Unscrew the union nut, remove the glass or coloured
glass and the O ring, check for damage, replace, if necessary, then remove the defective bulb from the housing (B1).
The OASE accessories include red, orange, green and blue coloured glass.
Important! Only original bulbs from OASE may be used.
Insert new bulb (do not touch, use a cloth or similar). Reassemble the unit in the reverse order, connect to the power
supply and perform a function check (B2).
Malfunctions
S
Malfunction
Lamp does not light up
Light intensity decreases
Water in the spotlight housing
10
2
and H07RN-F 2
Cause
Power supply interrupted
Bulb defective
Contact pins at the bulb corroded
Lamp glass soiled
Seal defective
2
1.5 mm
. Remove the cable lead through to
×
Remedy
Check power supply
Replace bulb
Clean contact pins
Clean
Check sealing rings and replace, if necessary

Publicidad

Tabla de contenido
loading

Tabla de contenido