7.2.
HYDRONOVA PLUS MODEL
Below there is a basic diagram (not functional) of a typical hydraulic installation.
Open
expansion
vessel
Safety valve
Drainpipe
Thermowell
Going
Return
•
Connection to the heating circuit
The model has in the rear, in the right upper part (seen from behind), a 1" connector. We
will use this connector in order to connect the output of the heating circuit (one way).
(see drawing D7.6).
At the rear, at the bottom left part, you will find another 1" connector. We will use this to
connect the return heating circuit (see drawing D7.6).
In this model, it is MANDATORY that the installer must
provide in the hydraulic installation, the placement of a
thermostatic cooling valve, whose mission is to lower
the temperature of the water, providing cold water
from the network, if it rises above 90 º C (see drawing
D7.8). This valve can be purchased optionally at the
Bronpi distributor where you acquired your thermostove
(VAL-05).
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Hot water
Pump
Anti-condesation valve
Thermowell connection
D7.7
Water network
Radiator
Cold water
• Connection of safety elements
This thermo-stove has the possibility of connecting a thermowell to
introduce a fluid temperature reading sensor. This connection is located at
the rear in the upper left part (seen from behind) and corresponds to the
connection of ½" located to the left (see drawing D7.7):
D7.8
28
Going
Return
D7.6
HYDRO RANGE