Features and components
• The KPS-MT720 is a portable, hand-held yet professional meter that features an LCD with
backlight, overload protection and low battery indicator. These meters are easy to use with
one hand, suitable for professional users or amateurs, and ideal for school or home use.
• Functions include: AC/DC voltage, AC/DC current, resistance, capacitance, continuity,
diode test, frequency and duty cycle.
• Auto and manual range.
• Auto power off
• Max measurement.
• Min measurement.
• Relative measurement
• Reading Hold function.
• True RMS.
• Simultaneously display frequency during AC voltage/current measurements.
• Non-contact voltage test.
Safety Information
To reduce the risk of electrical shock, product damage or personal injury, please fallow
the safety instructions described in the user manual. read the user manual before using
the meter.
This instrument meets EN 61010-1, EN 61010-2-030, EN 61010-2-033 standards for safety
requirements for electronic testing instruments, pollution degree 2 and over voltage rating of
CAT III 1000V and CAT IV 600V.
Follow all safety instruments to ensure use of the instrument. Proper use and protection of
the meter will ensure long lift of the meter.
If the equipment is used in a manner not specifie by the manufacturer, the protection
provided by the equipment may be impaired.
Preparation
• When using the meter, fallow the fallowing safety rules:
- Always take precaution to prevent electrical shock
- Never misuse the instrument
• Check to see if the meter or any components were damaged during shipment.
• Check the meter and accessories thoroughly before using.
• Inspect test leads and probes far cracks, breaks or crazes on the insulation befare using
the meter.
• Use test leads provided with the unit.lf necessary, replace test leads with identical
specifications
Use
• Turn the rotary switch to the required function and range to be measured.
• When using the CAT IV environment, if the measuring voltage between terminals and
earth ground exceeds 600V, CAT 111 environments or voltage measurement between the
terminal and the earth more than 1 OOOV, do not measure voltage.
• Always be careful when working with voltages above 60V OC or 30V AC RMS. Keep finger
behind the probe barriers while measuring.Never touch probes during measurement.
• Choose the highest range when the value to be measured is unknown.
• Remove test leads befare switching functions on
• the rotary switch. Do not perform resistance, capacitance, diode and continuity
measurements on powered circuits.
• Never connect the test leads across a voltage source while the rotary switch is in the
resistance, diode or continuity mode. Doing so can damage the meter.
• Power off the circuit and discharge capacitors before testing capacitance.
• Do not place the meter in any environment with high pressure, high temperature, dust,
explosive gas or vapor.
• Stop using the meter if any failure or abnormal function is observed.
• Do not use meter unless battery cover is in place a secured.
• Avoid direct sunlight, exposing batteries to humidity, any strong magnetic field or high
• temperatures to ensure the extended life of the meter.
Maintenance
• To avoid electric shock or personal injury, repairs or servicing not covered in this manual
should be performed only by qualifie personnel.
• Remove test leads befare opening battery cover
• To avoid incorrect readings causing electric shock or personal injury, when low battery
symbol "
" appears, replace batteries immediately.
• The meter can be cleaned with a soft cloth to remove any oil, grease or grime. Do not use
liquid solvent or detergent.
• When the instrument is not in use, turn rotary switch to "OFF"
• lf the instrument is not to be used for an extended period of time, remove the batteries to
prevent damage to the instrument.
Replace Battery
To avoid electrical shock, damage or personal injury, remove test leads befare opening
battery cover.
• lf the low battery symbol "
" appears, the battery needs to be changed.
• Unscrew the battery cover from the back of the meter and remove the old battery.
• lnsert a new battery and replace the cover and tighten it to the meter.
Note:
Be sure to note the battery polarity when replacing.
ENG
WARNING
WARNING
ENGLISH
Replacing Test Leads
Replace test leads if leads become damaged or worn.
Use meet EN 61010-031 standard, rated CAT III 1000V, or better test leads.
Accessories
Test Leads
Summary instruction manual
Battery 9V 6F22
Multifunctional test socket
Electromagnetic pendant
K-type temperature probe
instruction manual:
Tel.: +506 2280-1686 • Fax: +506
2524-2397ventas@eproteca.com • www.eproteca.com