Measuring negative pressure
in the combustion chamber
Above the combustion chamber opening, behind the up-
per door, there is a measuring duct on which the nega-
tive pressure in the combustion chamber can be meas-
ured with the door closed during heating operation.
measuring duct

Replacement parts

Attention:
Please ask your specialist trader for any replacement
We guarantee a ten-year availability of spare parts.
is imperative that you send us the type and fabrication
number given on the stove's rating plate.
storing compartment.
We recommend the relevant numbers here before in-
stalling the stove to ensure that you always have them
to hand:
Type number: 23/__________
Fabrication number: __________________________
parts required. Always use original spare parts only.
In order to process your order as quickly as possible, it
The stove identification plate is situated in the wood

What to do if ...?

... the stove doesn't draw properly?
● Is the chimney or the stovepipe not tight?
● Has the chimney been incorrectly designed?
● Is the external temperature too high?
chimney open?
... the room doesn't get hot?
● Is the waste gas pipe blocked?
● Is the combustion air supply been closed?
● Is the chimney draught too low?
● Is the wood used as fuel not dry?
... the stove gives off too much heat?
● Is the combustion air supply open too wide?
● Is the delivery pressure too high?
... the grate becomes damaged or slags are formed?
● The stove was overloaded.
● The ash pan was not emptied in good time.
... a fault occurs?
● Do not add any more fuel.
● Do not open the combustion chamber door.
controlled fashion.
● Are the doors of other fireplaces connected to the
department.
● Inform the chimney sweep.
● Is the heating requirement too high?
● Have a professional determine the cause?
● Allow the fire in the chimney to burn itself out in a
... the chimney catches fire?
● Minimize the air supply to the stove and call the fire