Positioning above the housing
structure.

ELECTRICAL CONNECTIONS

THE APPLAINCE IS SUPPLIED WITHOUT A PLUG TO CONNECT TO THE POWER SUPPLY LINE.
THE PRODUCER IS RELIEVED FROM ANY RECOURSE IF THE CONNECTIONS ARE PERFORMED BY THE
USER OR UNQUALIFIED STAFF.
- Check integrity of the power supply cable. If it is damaged, have it replaced by qualified staff
- The electric power supply must be compatible with the indications given on the electric diagram.
- A master switch must be available for the connection it must be omnipolar, which interrupts all contacts excluding
the neutral, with distance between open contacts of at least 3 mm, with magnet circuit breaker trip or coupled to
fuses, to be dimensioned or calibrated in compliance with the power indicated on the machine plate.
- The master switch must be on the electric line near to the installation and must only serve one appliance at a time
- An efficient EARTH plant must already be present, to which the machine must be connected
- Adapters, multiple sockets, cables with inadequate section or extension joints that are not in compliance with
specific requests of the standards in force must be excluded
- For details regarding electrical functioning, consult the diagram attached to the manual or positioned on the back
of the machine
- The power supply cable cannot be pulled or crushed during normal functioning or routine maintenance.
K = Air conveyors
Correct installation
Adequate air conveyors must be inserted inside of the
housing structure guaranteeing an air flow as indicated by
the arrows.
Encased positioning in line with the
level of the housing structure.