Buzzer and alarm
Alarm
relay
E0
active
E1
not active
IA
active
L0
active
HI
active
EE
not active
Ed
not active
dF
not active

ON-OFF SWITCH

This switch does NOT isolate the electrical line.
If OFF, it turns the control unit and cover movement off (if present).
If OFF, the electrical panel and light still remain electrically powered.
If ON, it turns the control unit and cover movement on (if present).
MOVEMENT SWITCH
This switch is supplied only on Tradition models.
It activates movement of the structure on top.
It must be kept pressed to allow the mobile cover to open or close.

LIGHT SWITCH

This switch turns the light on and off.
Alarm description
regulation probe error
defrosting probe error
immediate or delayed external alarm from A7
low temperature alarm
high temperature alarm
data storage error
defrosting ended for time out
defrosting on
Condition
if probe present
if digital input present
if enabled