Enofrigo MUSIC Serie Manual De Instrucciones página 76

Ocultar thumbs Ver también para MUSIC Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

13.4.4 Storing the new values assigned to the parameters
To definitively store the new values of the modified parameters, press
than 5 seconds, thus exiting the parameter setting procedure. All the modifications
made to the parameters, temporarily stored in the RAM, can be cancelled and "normal
operation" resumed by not pressing any button for 60 seconds, thus allowing the para-
meter setting session to expire due to timeout.
Important: if the programming session ends by timeout, the clock parameters will not
be reset, as these parameters are saved immediately when entered. If the instrument
is switched off before pressing
temporarily saved will be lost.
13.4.5 Classification of the parameters
The parameters, as well as being divided by TYPE, are also grouped into logical CATE-
GORIES identified by the initial letters or symbols. The following table lists the catego-
ries and the corresponding letters.
Parameters
Temperature probe management
/
r
Temperature control parameters
c
Defrost management parameters
d
Alarm management parameters
A
F
General configuration parameters
H configuration
H haccp
rtc
13.4.6 Set point regolation (main temperature) (to see 13.7-13.11 paragraph)
To display or set the set point, proceed as follows:
1) Press
2) Increase or decrease the set point using the
reaching the desired value;
3) Press
Code CT55900010
Category
parameters
Compressor safety time and
activation parameters
Fan management
parameters/2^temperature
(addresses,enabling,etc)
HACCP parameters
RTC parameters
for more than 1 second to display the set point;
again to confirm the new value.
, all the modifications made to the parameters and
Text
Pro
Ctl
CMP
dEF
ALM
Fan
CnF
HcP
rtc
and
English - 28
for more
Icon
buttons respectively, until
Rev. 03 - 07/'06

Publicidad

Tabla de contenido
loading

Tabla de contenido