Congratulations on your purchase and thank you for choosing our unit. Our goal is
to fully satisfy consumers by offering them cutting-edge systems for the treatment
of respiratory tract ailments. Read these instructions carefully and retain them
for future reference. Only use the accessory as described in this manual. This
is a home medical device to nebulise and administer medication prescribed or
recommended by your doctor upon assessing the patient's general conditions.
Please visit www.flaem.it to see the entire range of Flaem products.
THIS DEVICE COMES EQUIPPED WITH:
Aerosoltherapy unit (main unit)
A -
A1 - On/off switch
A2 - Air outlet port
A3 - Air filter
A4 - Nebuliser holder
A5 - Carrying handle
A6 - Power cord
Connection tube
B -
(main unit / nebuliser)

IMPORTANT SAFEGUARDS

• This device is also intended for direct use by the patient.
• Before using the product for the first time, and periodically during its lifetime, check
the integrity of the device structure and of the power cable to make sure there is
no damage. In the event of damage, do not plug in the cable and immediately take
the product to an authorised FLAEM service centre or to your trusted dealer.
• Should your device fail to provide the expected performance, contact the
authorised service centre for clarifications.
• The expected medical life of the accessories is 1 year. It is, however, advisable to
replace the nebuliser cup every 6 months in the event of intense use (or earlier if
the cup is obstructed) to always guarantee maximum therapeutic efficacy.
• Children and people who are not self-sufficient must use the device under the
close supervision of an adult who has read this manual.
• Some parts of the device are small enough to be swallowed by children; therefore,
keep the device out of the reach of children.
• Do not use the supplied tubing and cables for anything other than their intended
use. These parts could cause a strangling hazard: pay close attention to children
and persons with particular difficulties as they are often unable to accurately
evaluate danger.
• The apparatus is unsuitable for use in presence of flammable anaesthetic mixture
with air, oxygen or nitrous oxide.
• Always keep the power supply cable away from hot surfaces.
• Keep the power cable away from animals (for example, rodents) which could
damage the insulation.
• Do not handle the device with wet hands. Do not use the device in damp
environments (for example, while taking a bath or shower). Do not immerse the
device in water; in the event of immersion immediately disconnect the plug. Do not
MasterNeb
Mod. P0404EM F400
AEROSOL THERAPY UNIT
C -
1
Accessories
2
C1 - RF6 Basic
nebuliser
C1.1 - Lower part
C1.2 - Complete nozzle
C1.3 - Upper part
C1.4 - Top ventilation cap
C2 - Mouthpiece
C3 - Pediatric mask
C4 - Adult mask