INSTRUCTION MANUAL (Translation from the original Spanish)
Damage prevention and safety instructions
A
Warning! Observe limitations of use.
B
The name plate voltage must be the same as the
mains voltage.
C
Connect the pump to the mains via an omnipolar
switch with at least a 3mm opening between contacts.
D
Install a high-sensitivity differential switch (0.03A)
as extra protection against lethal electric shocks.
E
Connect the pump to the ground.
F
Use
pump
only
indicated on the name plate.
G
Remember to prime pump.
H
Check for motor self-ventilation.
Contents
Safety precautions .................................................. 10

1. General information ........................................... 10

2. Handling ............................................................. 10
3. Installation ......................................................... 11
3.1. Fixing ............................................................ 11
3.2. Suction pipe assembly ................................. 11
3.3. Discharge pipe assembly ............................. 11
3.4. Electrical connection..................................... 11
3.5. Pre-start checks ............................................ 11
4. Start-up .............................................................. 11
4.1. Start-up and operation .................................. 11
4.2. Default pressure adjustment ........................ 12
4.3. LED indicators .............................................. 12
4.4. Automatic reset ............................................. 12
5. Level switch ....................................................... 12
6. Maintenance ...................................................... 13
7. Disposing of the product .................................... 13
8. Nameplate ......................................................... 13
10. Technical data ................................................... 13
11. List of main components .................................... 53
12. Wiring diagrams ................................................. 54
13. Illustrations ......................................................... 54
Safety precautions
This symbol
following words "Danger" or "Warning" indicates the
risk level deriving from failure to observe the
prescribed safety precautions:
DANGER
Warns that failure to observe
risk of electric
the pre cautions involves a
shock
risk of electric shock.
DANGER
Warns that failure to observe
the pre cautions involves a
risk of damage to persons
and/or things.
WARNING
Warns that failure to observe
the pre cautions involves the
risk of damaging the pump
and/or the facility
within
performance
limits
together with one of the
(See figure 4)
I
This apparatus may be used by children 8 years
or older and persons with reduced physical,
sensory
or
mental
experience and knowledge, if they are supervised
or receive adequate training on the safe use of the
apparatus and understand the dangers.
Children should not be allowed to play with the
apparatus.
Children should not perform the ordinary cleaning
and maintenance tasks without supervision.
J
Be
careful
with
environments.
K
Caution! Look out for accidental leaks.
Do not expose pump to bad weather.
L
Caution! Avoid icing.
Cut out power supply before servicing pump.
1. GENERAL INFORMATION
Please observe the following instructions to achieve
the best pump performance possible and a trouble
free installation.
Read these instructions before installing the
pump.
Save them for future reference.
They are horizontal multistage centrifugal pumps,
made up of several in-line impellers which provide
the same flow rate with different pressures,
according to the number of impellers in place.
These pumps are designed to operate with clean
water, free from particles in suspension and at a
maximum temperature of 40ºC.
The TECNOPLUS 25 pump with built-in electronic
pressure regulator consists of a check valve,
indicator LEDs and electronic control.
It has been designed to automate the starting and
stopping of a pump, changing the motor speed to
maintain a constant pressure. The electronic control
also prevents dry running pump.
While a faucet is left running, the pump continues to
run; when faucets are closed, the pump stops.
Correct pump operation is assured providing
the instructions on electrical connection,
installation and use are strictly adhered to.
Failure to adhere to the instructions can
result in premature failure of the pump and
voiding of the warranty.
2. HANDLING
The pumps are supplied suitably packaged to pre-
vent damage in transit. Before unpacking, check
that the packaging has not been damaged or de-
formed,
Lift and handle the product with care and with
the right tools.
10
EN
capacities,
or
lacking
hazardous
liquids
and

Publicidad

Tabla de contenido
loading

Tabla de contenido