Mounting instructions for electricians
14. Electrical connection:
Caution:
Unit with direct connection: shorten the connection
cable and connect it to the floor outlet with less
cable excess.
The wash unit with power supply cable must not be
connected to the power supply using an extension
cable.
Arrange the power supply cable so that the plug is
easily accessible and can be isolated from the wall
socket.
In case several wash units are to be installed in-line,
the power supply cable must not be connected via
further units.
The safety regulations of the hairdressing trade must
be observed. Installation and operation must be in
accordance with the norm DIN VDE 0100.
During assembly work the complete system
must be isolated from the power supply and
secured against unintended switch-on!
In the wash unit, use only the plug-in connectors
supplied with the appliance and specified in the
mounting instructions!
Cables must be so arranged that they are not in the
vicinity or moving parts! Damage or crushing must
thus be prevented!
The power supply cable from the unit must be
arranged so that it is not jammed between the unit
frame and the floor.
The mains cable must be led outward completely and
provided with strain relief
For reasons of mechanical security as well as the
electromagnetic compatibility no cable excess may be
stowed away in the shampoo unit.
Variants for single units:
14.1
Direct wiring variant: (Fig. 6)
Caution: This type of connection must only be
made by a qualified electrician!
- Replace plug of power supply cable with the system
plug supplied (Fig. 4)
- Connect power supply cable from the floor to the
system socket supplied (Fig. 4)
- Plug system plug into the system socket and close
safety catch (Fig. 5).
14.2
Mains cable variant: (Fig. 7)
Route the mains plug to the outside.
In-line installation variants:
14.3
In-line installation with direct wiring (Fig. 8)
> Connection s. 16.1
14.4
In-line installation with plug/socket (Fig. 9)
> Connection s.16.2
Comfort
MO B+R
GB
Mounting instructions for appliance fitters
15.
Assembly:
15.1
Using a cable tie, hold the 2 pressure hoses (hot + cold)
loosely together.
15.2
Attach front housing (3 + 4):
Push housing components in the reverse order as in fig.
3 onto the column housing (1) and close the magnet
connector.
Attach housing components (3 + 4) via the hexagonal
socket screw inside to the column housing. Check that
housing components fit correctly. Otherwise unscrew
the fasteners and re-align the components, then re-
tighten screws.
15.3
Replace bottom cover of chair (7): press it tightly in
place, first at the rear then at the front.
(velcro fastener)
15.4
Replace and close inspection door (5).
15.5
Place the remote control on the decorative button at
the side of the backrest (holds magnetically).
16.
Servicing
The backrest upholstery as well as the backrest cover
can be removed for servicing:
- Pull backrest upholstery (8) upwards
- Pull back backrest cover rearwards (9)
(Velcro fastening)