Distance between blade and cou-
nter-blade
For the proper functioning of the machine and

a great result in the material crushed by the
side entrance funnel, care must be taken in the
distance between the blade (1) and counter-blade
(2), this measure should be 3 mm with tolerance
+/- 0.4 mm.
The only lubrication points are wheels for

transporting the machine (1).
Lubrication should be performed periodically

through the grease fitting (A). Use bearing grease.
The total amount of grease is 10 grams for each

application which must be done once every 30 days
and more often if the machine is used frequently.
Maintenance motor a gasoline
In the first 5 hours
Change the oil of the crankcase

Every 8 hours or daily
Check the oil level

Clean the area around the muffler and the controls

Clean the protective screen

Every 25 hours or annually
Clean the air filter

Clean the pre-purifier

Every 50 hours o annually
Change the engine oil

Check the muffler and spark arrester

Annually
Replace the oil filter

Replace the pre-purifier

Replace the spark plug

Replace the fuel filter

Clean the air cooling system

Note: 1) In very dusty places or when particles brought by the air are present, clean more frequently.