AVENTICS | PROFIBUS DP | R402003657–BAL–001–AG
1. Double-click the symbol Profibus/M.
The settings window is opened.
2. Enter the address in the Busadresse box. Typically the
address 1 is used for the master, or change the value by
clicking the arrow keys.
3. On the tab Busparameter (Bus parameters), select the
desired data rate (Baudrate) from the list of possible rates.
To show the library of the various PROFIBUS components:
1. In the Ansicht (View) menu, select the menu item Bibliothek
(Library).
2. Below the panel Peripherie, click ProfibusDP/Ventile in the
library tree.
The components of AVENTICS are shown.
3. Using the mouse, drag the module BDC-B-DP_32 to the
dotted line in front of the Profibus master.
As it is not a modular device, a module with 4-byte outputs
Commissioning and operation
79