11 Technical Data - Aventics PROFIBUS DP Instrucciones De Servicio

Ocultar thumbs Ver también para PROFIBUS DP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 187
90
AVENTICS | PROFIBUS DP | R402003657–BAL–001–AG
Technical Data
General data
Dimensions
Weight
Operating temperature range
Storage temperature range
Protection to EN 60529/IEC529
Compressed air quality
Working pressure
Nominal flow
Mounting orientation
Electrical data
Operating voltage
- Electronics U
L
- Load U
, U
Q1
Q2
- Current I
L
Protection for the power supply
Protection for logic voltage
Line length for power supply
Current in 0 V line
Internal voltage drop
Output current per valve output
Run-up time
No. of outputs
No. of output bytes

11 Technical Data

Depend on configuration; see product catalogue.
Depend on configuration; see product catalogue.
0 °C to +50 °C, without condensation
–20 °C to +70 °C
When assembled: IP 69K
To DIN ISO 8573-1, class 6, 4, 3 or lower
solid pollutants: ≤ 5 μm
dew point: ≤ 3 °C
oil content: ≤ 1 mg/m
2.5 - 10 bar
950 - 1100 std. l/min, depending on valve type and subbase
at 6 bar pilot pressure, Δ = 1 bar
Any
24 V DC (+20%/-15%)
24 V DC (15 %)
50 mA
2 x 3.0 A (F)
500 mA (F)
Max. 20 m
Max. 4 A
0.6 V
Max. 100 mA
Approx. 1 s
Max. 32
Fixed, output 4 bytes and input 0 bytes
The corresponding declaration of conformity is included on CD
R412023902.
3

Publicidad

Tabla de contenido
loading

Tabla de contenido