English
12. LED light warning signals (Fig. 16)
This product features functions that are designed
to protect the tool itself as well as the battery. While
the switch is pulled, if any of the safeguard functions
activate during operation, the LED light will blink as
described in Table 8. When any of the safeguard
functions are triggered, immediately remove your
fi nger from the switch and follow the instructions
described under corrective action.
Safeguard Function
Overburden Protection
Temperature Protection

OPERATIONAL CAUTIONS

Resting the unit after continuous work
(1) The power tool is equipped with a temperature
protection circuit to protect the motor.
Continuous bolt-tightening work may cause the
temperature of the unit to rise, activating the
temperature protection circuit and automatically
stopping operation.
If this happens, allow the power tool to cool before
resuming use.
(2) After use for continuous tightening wood screw works,
rest the unit for 15 minutes or so when replacing the
battery. The temperature of the motor, switch, etc.,
will rise if the work is started again immediately after
battery replacement, eventually resulting in burnout.
16
0000Book_DS18DDX.indb 16
0000Book_DS18DDX.indb 16
Table 8
LED Light Display
On 0.1 second/off 0.5 second
On 0.3 second/off 0.3 second
Fig. 16
Corrective Action
If the operating with the shift knob set on
HIGH, adjust to LOW and continue operation.
Remove the cause of the overburdening.
Allow the tool and battery to thoroughly cool.