Electric Heating Toggle; Locating The Connecting Box For The Connection Cable In The Sauna Room - Helo OCTA Instrucciones De Uso E Instalación

Sauna electric
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 58
Installation and User Manual OCTA

3.4 Electric heating toggle

The electric heating toggle applies to homes with an electric heating system.
The contactor case has a connection (marked 55) for controlling the electric heating toggle.
Connector 55 and the heating elements are simultaneously live (230V). Refer to the contactor case operating man-
ual for more specific instructions.
A
A
A
Image. 2 Location for the connection box

3.5 Locating the connecting box for the connection cable in the sauna room

A = Specified minimum safety clearance, see table 2.
1. Recommended location for the connecting box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The
connection box must be clear of obstacles. When installing the connection box to zones 2 or 3,
refer to the instructions and regulations of the local energy supplier.
Sauna Heaters
Effect
connection cable
H07RN-F /
60245 IEC 66
2
kW
mm
400 – 415V 3N~
9,0
5 x 2,5
10,5
5 x 2,5
12,0
5 x 6
15,0
5 x 6
Table 1 Connection cable and fuses
A
A
A
3.
2.
Fuse
A
3 x 16
3 x 16
3 x 25
3 x 25
1.
6

Publicidad

Tabla de contenido
loading

Tabla de contenido