Registro De Explotación - Carel μChiller Manual Del Usuario

Tabla de contenido

Publicidad

Index
Size
Ref.
71
1
A72
72
1
A73
73
1
A74
74
1
A75
75
1
A76
76
1
A77
77
1
A78
78
1
A79
79
1
A80
80
1
A81
81
1
82
1
83
1
84
1
102
1
103
1
104
1
105
1
106
1
107
1
108
1
109
1
110
1
119
1
A87
120
1
121
1
122
1
123
1
124
1
125
1
127
1
128
1
129
1
131
1
132
1
134
1
143
1
144
1
145
1
146
1
148
1
7.3
Registro de explotación
Index
Size
Ref.
2
1
U000
3
1
U002
4
1
U003
5
1
U005
7
2
U006
9
2
U007
11
2
U008
13
2
U009
15
2
U011
17
2
U012
19
2
U013
21
2
U014
23
2
U015
25
2
U016
27
1
U018
28
1
U019
29
1
U020
30
1
U021
31
2
U023
33
2
U024
35
1
U025
37
2
U026
39
2
U027
41
1
S023
42
1
S024
43
2
U028
μchiller +0300053ES rel. 2.0 - 07.07.2020
Type
Min/Max
R/W
UoM Description
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
Type
Min/Max
R/W
UoM
INT
0..999
R/W
h
INT
0..2
R/W
INT
0..999
R/W
h
INT
0..2
R/W
REAL
-99.9..999.9
R/W
°C/°F
REAL
-99.9..999.9
R/W
°C/°F
REAL
0..999.9
R/W
°C/°F
REAL
0..999.9
R/W
°C/°F
REAL
R/W
°C/°F
REAL
-99.9..99.9
R/W
°C/°F
REAL
-99.9..99.9
R/W
K/R
REAL
-999.9..999.9
R/W
°C/°F
REAL
-99.9..99.9
R/W
°C/°F
REAL
-99.9..99.9
R/W
K/R
INT
0..23
R/W
h
INT
0..59
R/W
min
INT
0..23
R/W
h
INT
0..59
R/W
min
REAL
U006..U007
R/W
°C/°F
REAL
U008..U009
R/W
°C/°F
INT
0..2
R/W
REAL
-99.9..99.9
R/W
°C/°F
REAL
-99.9..99.9
R/W
°C/°F
INT
0..23
R/W
h
INT
0..59
R/W
min
REAL
-99.9..99.9
R/W
K/R
Circuit 2 EVD - Emergency closing
Circuit 2 EVD - Incomplete valve closing
Circuit 2 EVD - Offline
Circuit 2 Envelope - General alarm + Alarm zone
Circuit 2 BLDC - Delta pressure greater than the allowable at startup
Circuit 2 BLDC - Starting failure
Circuit 2 BLDC - Low differential pressure
Circuit 2 BLDC - High discharge gas temperature
Circuit 2 Inverter - Offline
Circuit 2 Inverter - General alarm + Error code
PrevAFreeze_C1 - Prevent request for antifreeze condition active inside circ.1
PrevHP_C1 - Prevent request for high pressure condition active inside circ.1
PrevAFreeze_C2 - Prevent request for antifreeze condition active inside circ.2
PrevHP_C2 - Prevent request for high pressure condition active inside circ.2
Comp1Circ1_On - Compr.1 circ.1 status (0=OFF 1=ON)
Comp2Circ1_On - Compr.2 circ.1 status (0=OFF, 1=ON)
Comp1Circ2_On - Compr.1 circ.2 status (0=OFF, 1=ON)
Comp2Circ2_On - Compr.2 circ.2 status (0=OFF, 1=ON)
RelayAlrm - Global alarm relay
CoolHeat - Unit in heating mode (0=Cooling, 1=Heating)
FC_Status - Free cooling valve status (0=OFF, 1=ON)
Antifreeze heater status
Unit scheduler status
EVD - Alarm Hw incompatible
SrcFanCirc1_On - Source fan circ.1 status (0=OFF, 1=ON)
SrcPmp1_On - Source pump 1 status (0=OFF, 1=ON)
UsrPmp1_On - User pump 1 status
RevVlv_Circ1 - Reverse valve for circ.1 (0=Cooling, 1=Heating)
Oil equalization valve circuit 1 status
SrcFanCirc2_On - Source fan circ.2 status (0=OFF, 1=ON)
UsrPmp2_On - User pump 2 status
RevVlv_Circ2 - Reverse valve for circ.2 (0=Cooling, 1=Heating)
Oil equalization valve circuit 2 status
Defrost running on circuit 1
Defrost running on circuit 2
Unit status
Compr.1 circuit 1 forced on by oil migration management
Compr.2 circuit 1 forced on by oil migration management
Compr.1 circuit 2 forced on by oil migration management
Compr.2 circuit 2 forced on by oil migration management
UsrFlw_Absent - User pump flow absent (0=Flow OK, 1=Flow absent)
Description
U000 - User pump 1 maintenance hour threshold (x100)
U002 - User pump 1/fan manual mode (0=AUTO, 1=OFF, 2=ON)
U003 - User pump 2 maintenance hour threshold (x100)
U005 - User pump 2 manual mode (0=AUTO, 1=OFF, 2=ON)
U006 - Cool setpoint low limit
U007 - Cool setpoint high limit
U008 - Heat setpoint low limit
U009 - Heat setpoint high limit
U011 - Starting temp. point for cool setpoint compensation
U012 - Ending temp. point for cool setpoint compensation
U013 - Max compensation for cool setpoint
U014 - Starting temp. point for heat setpoint compensation
U015 - Ext. temp. diff. point for heat setpoint compensation
U016 - Max compensation for heat setpoint
Time band hour
Time band minute
Time band hour
Time band minute
U023 - 2nd cool setpoint
U024 - 2nd heat setpoint
U025 - Analog setpoint input type (0=0-5V, 1=0-10V, 2=4-20mA)
U026 - Remote setpoint min value
U027 - Remote setpoint max value
Time band hour
Time band minute
U028 - Remote setpoint offset
SPA
Tab. 7.m
87

Publicidad

Tabla de contenido
loading

Tabla de contenido