Index
Size
Ref.
286
1
Hc00
287
1
Hc01
288
1
Hc03
289
1
Hc04
290
1
Hc05
291
1
Hc06
292
1
Hc07
293
1
Hc08
294
1
Hc09
295
1
Hc10
296
1
Hc11
307
2
SEtC
309
2
SEtH
324
2
C017
326
2
C018
328
1
E047
335
2
P000
337
2
P001
339
1
P002
340
1
P003
341
1
P004
342
2
P005
344
2
P006
346
2
P007
348
1
P008
349
1
P009
350
2
P010
352
1
P011
353
1
P012
354
1
P013
355
1
P014
356
1
P015
357
1
P019
358
1
P020
359
2
P021
361
1
P022
362
1
P023
363
2
P024
365
2
P025
367
2
P026
369
2
P027
371
2
P028
373
2
P029
375
2
P030
377
2
P031
379
1
P032
380
1
P033
382
2
S051
384
2
S052
703
1
704
1
709
1
U079
710
1
U080
732
2
S070
734
2
S071
736
2
S069
90
Type
Min/Max
R/W
UoM
INT
0..3/4
R/W
INT
0..1
R/W
INT
0..2
R/W
INT
0..1
R/W
INT
0..1
R/W
INT
0..6
R/W
INT
0..6
R/W
INT
0..6
R/W
INT
0..5
R/W
INT
0..5
R/W
INT
0..5
R/W
REAL
U006..U007
R/W
°C/°F
REAL
U008..U009
R/W
°C/°F
REAL
0..999.9
R/W
°C/°F
REAL
-99.9..99.9
R/W
bar/psi C018 - Threshold of min low pressure (LP)
INT
0..2
R/W
REAL
-999.9..999.9
R/W
°C/°F
REAL
-999.9..999.9
R/W
°C/°F
INT
0..999
R/W
s
INT
0..999
R/W
s
INT
0..999
R/W
s
REAL
0..999.9
R/W
rps
REAL
0..100
R/W
%
REAL
0..999.9
R/W
rps
INT
0..999
R/W
min
INT
0..999
R/W
min
REAL
0..999.9
R/W
rps
INT
0..999
R/W
s
INT
0..999
R/W
s
INT
0..999
R/W
min
INT
0..999
R/W
min
INT
0..999
R/W
min
INT
0..101
R/W
%
INT
0..101
R/W
%
REAL
R/W
kPa
INT
R/W
s
INT
R/W
%
REAL
R/W
rps
REAL
R/W
rps
REAL
R/W
rps
REAL
0..100
R/W
%
REAL
20..100
R/W
%
REAL
20..100
R/W
%
REAL
R/W
REAL
R/W
INT
R/W
INT
R/W
REAL
0..999.9
R/W
rps
REAL
0..999.9
R/W
rps
INT
R/W
INT
R/W
INT
1..15
R/W
min
INT
3..99
R/W
min
REAL
-99.9..99.9
R/W
K/R
REAL
99.9..99.9
R/W
K/R
REAL
0..99.9
R/W
°C/°F
Description
Hc00 - Analog input 3 config. (0=Not used, 1=Source temp.,
2=Discharge temp., 3=Suction temp., 4=Source water delivery temp.)
Hc01 - Analog input 4 and 5 config. (0=Pressure, 1=Temp.)
Hc03 - Analog input 6 config.
(0=Not used, 1=Remote setpoint, 2=Source temp.)
Hc04 - Analog input 7 config.(0=Not used, 1=Suction temp.)
Hc05 - Analog input 6 config. of Circuit 2 board
(0=Not used, 1=Remote setpoint)
Hc06 - Digital input 4 config. (0=Not used, 1=Compr.2 circ.1 overload,
2=Remote ON/OFF, 3=Cool/Heat, 4=2nd SetPoint, 5=Remote alarm ,
6=User pump 1 overload)
Hc07 - Digital input 5 config. (0=Not used, 1=Compr.2 circ.1 overload,
2=Remote ON/OFF, 3=Cool/Heat, 4=2nd SetPoint, 5=Remote alarm,
6=User pump 1 overload)
Hc08 - Digital input 6 config. (0=Not used, 1=Compr.2 circ.1 overload,
2=Remote ON/OFF, 3=Cool/Heat, 4=2nd SetPoint, 5=Remote alarm,
6=User pump 1 overload)
Hc09 - Digital input 4 config. of Circuit 2 board (0=Not used,
1=Compr.2 circ.2 overload, 2=Remote ON/OFF, 3=Cool/Heat,
4=2nd SetPoint, 5=User pump 1 overload)
Hc10 - Digital input 5 config. of Circuit 2 board (0=Not used,
1=Compr.2 circ.2 overload, 2=Remote ON/OFF, 3=Cool/Heat,
4=2nd SetPoint, 5=User pump 1 overload)
Hc11 - Digital input 6 config. of Circuit 2 board (0=Not used,
1=Compr.2 circ.2 overload, 2=Remote ON/OFF, 3=Cool/Heat
4=2nd SetPoint, 5=User pump 1 overload)
SEtC - Cool setpoint
SEtH - Heat setpoint
C017 - Threshold of max high pressure (HP)
E047 - Type of ExV driver (0= Disabled, 1= EVD embedded, 2=EVD EVO)
P000 - Evaporating min temp. custom envelop limit
P001 - Condensing max temp. custom envelop limit
P002 - Prevent min duration
P003 - Out of envelop alarm delay time
P004 - Low pressure difference alarm delay
P005 - Circuit destabilization min BLDC speed threshold
P006 - Oil recovery min request for activation
P007 - Oil recovery min compr. speed for activation
P008 - Oil recovery time before activation in which the compressor
can run at min speed
P009 - Oil recovery duration in which the compr. speed is forced
P010 - Oil recovery compr. speed in which the compr. is forced
P011- Oil equalization startup time of solenoid valve on compr. starts
P012 - Oil equalization solenoid valve open time
P013 - Oil equalization solenoid valve min off time
P014 - Oil equalization solenoid valve max off time
P015 - Oil equalization max time for the management
P019 - Compressor 1 circuit 1 manual mode (0=AUTO, 1=0%, ... 101=100%)
P020 - Compressor 1 circuit 2 manual mode (0=AUTO, 1=0%, ... 101=100%)
P021 - Max permitted Delta P to start up
P022 - Max time of EVD propening to equalize pressure
P023 - Preopening of EVD in case of prestart to equalize pressure
P024 - Start up speed
P025 - Max speed custom (rps)
P026 - Min speed custom (rps)
P027 - BLDC speed request threshold % to call on it
P028 - BLDC speed threshold to call on fixed speed compressor
P029 - BLDC speed threshold to switch off fixed speed compressor
P030 - Skip frequency: set 1 [010]
P031 - Skip frequency: band 1 [011]
P032 - Enable motor overtemperature alarm (PTC) (0=OFF, 1=ON) [027]
P033 - Motor overtemperature alarm delay [028]
S051 - BLDC defrost speed
S052 - BLDC cycle reverse speed in defrost
MotTyp - BLDC Carel Database ID
Poles - Number of motor poles
U079 - Burst funct. time of user pump on
U080 - Burst funct. time of user pump off
S070 - Cond.1 antifreeze temp. probe offset (S3)
S071 - Cond.2 antifreeze temp. probe offset (S3 exp.)
S069 - Temperature set point of Fan-Defrost function (0=Function disabled)
Tab. 7.n
μchiller +0300053ES rel. 2.0 - 07.07.2020