THERMO TECHNICAL CHARACTERISTICS according to EN 14785
Heat output
Yield / Efficiency
Emissions CO 13% O2
Maximum flue gas temperature
Minimum draught
Mass flow rate of flue gas
Fuel consumption
Hopper capacity
Autonomy
Volume riscaldabile *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging (glass/steel)
* The heatable room dimensions are calculated on the basis home insulation in compliance with Italian law 10/91, and subsequent
changes together with an expected heat output of 33 Kcal/m³ per hour.

ELECTRICAL CHARACTERISTICS

Power supply
On/off switch
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on mains power supply* (see page 25)
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) caution: live parts. Servicing and/or inspections must be carried out by qualified staff.
The data shown above is purely indicative.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.

SAFETY DEVICES

• THERMOCOUPLE:
Placed at the smoke outlet to detect the temperature.
Turns the stove on and off and controls its operation based on defined parameters.
• VACUUM GAUGE:
positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber.
• AIR FLOW SENSOR:
located in the suction channel, it is activated when the combustion air flow is not correct, with consequent pressure problems in
the smoke circuit causing the stove to shut-down.

• SAFETY THERMOSTAT:

Trips when the temperature inside the stove is too high. It stops pellet loading, causing the stove to go out.
• SAFETY PRESSURE SWITCH:
This is activated if the vacuum inside the combustion chamber is insufficient for it to function correctly.
CHARACTERISTICS
100
400
- 26
-
Nominal power
6,5
90,1
0,014
133
12 - 5
5,9
1,5
18
10
170
80
40
171 / 165
230Vac +/- 10% 50 Hz
Yes
Radio waves 2,4 GHz
2AT, 250 Vac, 5x20 Fuse
2AT, 250 Vac, 5x20 Fuse
Reduced power
2,4
kW
94,8
%
0,041
%
71
°C
10 - 3
Pa
2,6
g/s
0,5
kg/h
kg
30
hours
m
3
mm
mm
kg
W
W