Fitting the top flue pipe outlet kit
(FOR ALL VERSIONS)
During the installation use the silicon paste to seal between
the flue-gas extractor and the different connections of the flue
outlet.
- Remove the diaphragm (H - fig. 7) and, if necessary the per-
forated lower rear panel as well (I - fig. 7).
- Slacken the clamp (L - fig. 8) and remove the outlet flue pipe
(L1 - fig. 8).
- Position the inspection elbow (M - fig. 9) and fix it using the
clamp slackened previously.
- Remove the cast iron cap (N - fig. 10) resting on the top and
fit the flue pipe outlet (P - fig. 10) from the side of the stove.
- Position the two plating closers (Q - fig. 11) around the flue
pipe outlet and fix them using the screws.
- Fit the side removed previously (for the version with glass
sides, put the gaskets and small parts back in place as shown in
figure 12).
- Fit the flue pipe (R - fig. 13) (not supplied) over the outlet and
fix it using the clamp (S - fig. 13) (not supplied).