3.6

Fuses

Table 3-3: Fuses
Fuse
Main fuse F1, 230 V
Main fuse F1, 400 V
Main fuse F1, 460 V
Transformer, primary fuse F2 and F3
Transformer, secondary protection
F4
F5
*General size, see also the included electrical diagrams.
3.7

Main components

WARNING!
Explosion risk.
Never use the unit without an antistatic plastic bag.
Depending on the FlexPAK 800/1000 DX model used, treat its explosion protection
device carefully so that it does not become damaged, see figure 2.
CAUTION!
Risk of equipment damage.
Use Nederman original bags only.
NOTE! Depending on the FlexPAK 800/1000 DX, there is also an explosion protection
device, see figures 2A and 2B. See also section '3.3 Explosion protection'.
Figures 4A, 4B and 4C show the main components of the unit:
1.
Collector bin, see figure 4A.
2.
Dust extractor, see figure 4A.
3.
Textile filter bags, see figure 4A.
4.
Filter holder, see figure 4A.
5.
Filter Cleaning Valve (FCV), see figure 4A.
6.
Connection duct from the dust extractor to the inlet silencer, see figure 4A.
7.
Start and control unit, see figures 4A and 4B.
8.
Control panel, see figures 4A and 4B.
9.
Emergency switch, see figures 4A and 4B.
10.
Frequency converter, see figures 4A and 4B.
11.
Frequency converter cooling air filter, see figures 4A and 4B.
12.
Cooling valve, see figures 4A and 4B.
13.
High pressure side channel fan, with pump characteristic, see figures 4A and 4B.
14.
PT100 sensor, see figure 4B.
15.
Outlet silencer after fan, see figure 4B.
Size
65 A
35 A
40 A
0,8 A*
50 mA*
1 A*
FlexPAK 800/1000 DX
Type
Slow mains fuses
Slow mains fuses
Slow mains fuses
Slow fuses, 10.3×38
PTC resistor
Fast, 5×20
Slow, 5×20
EN
21