6.1
Connect dust extractor
WARNING
Risk of injury from tools starting up unex
pectedly
► Before switching on ensure that the con
nected tool is switched off.
► Insert the mains power cable in the cold-
device connector [2] and in an earthed sock
et.
► Lay the mains cable through the recess [2].
The switch [1-8] serves as an on/off switch.
Using the [1-9] switch, switch between the AU
TO and MAN settings.
"MAN" switch position
Appliance socket [1-10] is not connected to the
power, the dust extractor starts.
"Auto" switch position
Appliance socket [1-10] is connected to the
power, the dust extractor starts when the con
nected tool is switched on.
Pull the plug from the socket when the
machine is not in use and prior to main
tenance and cleaning work.
6.2
Connecting electric power tools
WARNING
Risk of injury
► Observe the maximum appliance socket
connected load (see chapter "Technical da
ta")
► Switch off the electric power tool.
► Connect the electric power tool to the appli
ance socket .
6.3
Connecting the suction hose
at the extraction opening [3a]
►
► Connect the suction hose to the elbow at the
extraction opening.
at the exhaust opening [3b]
► Open flap at rear of dust extractor.
► Connect suction hose to elbow at exhaust
opening.
7
Settings
7.1
Temperature monitoring
Before reaching a critical temperature, the
temperature monitor switches off the dust ex
tractor.
► Before reaching a critical temperature, the
temperature monitor switches off the dust
extractor.
► Switch off the dust extractor, allow to cool
for about 5 minutes, then switch on again.
Not possible to switch on: Contact Festool
customer service workshop.
7.2
Connect with the T-Loc
The dust extractor can be closed, opened and
connected by turning the T-Loc:
–
Close dust extractor [4a].
Open dust extractor [4b].
–
Connect dust extractor to storage box [4c].
–
Before lifting, always close the T-Loc at
the dust extractor or connect to the stor
age box and check for secure holding.
Max. load for connection to other Systainers: 20
kg
7.3
Use/Adjust carrying strap
Max. permissible load of carrying strap: 20 kg
The carrying strap can be attached in two dif
ferent positions:
–
Carrying the dust extractor: Carrying strap
at dust extractor [5a]
–
Carrying storage box with dust extractor:
Carrying strap at storage box [5b]
Before lifting, check the carrying strap for
proper functionality and put T-loc at dust ex
tractor into corresponding position.
Adjust the length of the carrying strap at the
adjusting tab [5c].
8
Working
CAUTION
Hazardous dust
Damage to the respiratory passage
► Always use a filter bag!
Two cleaning nozzles are stored in the in
side of the dust extractor [6-1].
Observe the following information:
–
The dust extractor is a stationary system
and not suitable for pulling at the cable and
hose. Use handle [1-4].
–
A static charge may build up if no antistatic
suction hose is used. The user may receive
an electric shock.
English
13