13. VISUALISATION OF PARAMETERS ON THE DISPLAY ("INFO" FUNCTION)

Press
for at least 6 seconds to display information concerning boiler operation.
When the "INFO" function is enabled, the message "A00" alternating with the boiler delivery temperature, is shown on the
display:
Press buttons
to display the following information:
A00: current heating delivery temperature (°C);
A01: current DHW temperature (°C);
A02: current external temperature (°C) (with external sensor connected);
A03: current fumes temperature (°C);
A04: instantaneous (%) value of the gas valve control signal;
A05: power range (%) (MAX CH);
A06: heating setpoint temperature (°C);
A07: DHW temperature setpoint (°C);
A08: last error that occurred in the boiler;
A09: not used;
A10: not used.
This function remains active for 3 minutes. It is possible to interrupt the "INFO" function in advance by pressing
the power to the boiler.

14. PARAMETER SETTINGS

To set the boiler parameters, press
display shows "F01" alternated with the value of the parameter.
Edit parameters
• To scroll the parameters press
• Press
buttons to change the single parameter value;
• Press
to save changes, the display shows "MEM";
• Press
to leave the function without saving, the display shows "ESC".
ALL MODIFIED PARAMETERS SHOULD BE NOTED DOWN IN THE TABLE AT THE END OF THIS MANUAL.
Parameter
F01
Boiler type 010=airtight chamber
F02
Gas used 000=NATURAL GAS - 001=LPG - 002=gas G25.1
F03
Hydraulic system
Setting programmable relays 1
F04-F05
000=no associated function
Maximum heating setpoint setting (°C)
F06
000=76°C (Burner goes out at 81 °C)
001=45°C (Burner goes out at 50 °C)
F07
DHW
inlet
priority configuration
F08
CH max. output (0-100%)
F09
DHW max. output
F10
CH and DHW min. heat output
Delay prior to new ignition in CH mode
F11
000=10 seconds - 001...010 = 1...10 minutes
F12
Identification of boiler model
F13
Factory
setting
F14
Test of correct DHW probe position 000=Disabled - 001=Always enabled
F15 - F16
Factory
setting
F17
Hydraulic pressure switch configuration
F18
Release parameters for SERVICE
7113156.01 (1-05/13)
and
together and hold down for at least 6 seconds. When the function is activated, the
;
Description of parameters
and 2
(See SERVICE instructions)
(0-100%)
(0-100%)
34
or turning off
Factory settings
24 F
18 F
010
000
002
000
000
002
055
100
100
000
003
001
002
000
001
000
001
000