Installation, Operating and
Maintenance Instructions
After eliminating the error cause the electrically locking can be reset. To do this,
please press the reset button of the error counter on the external control for at
least 6 seconds. Then a acoustic signal confirmes this process (1 s) and the error
counter will be deleted!
Installing the power supply unit (stabilized) - external control unit
0 V
blue
green / yellow
brown / black
Cable supplied by customer (min. 0,8 mm², e.g. JY(ST)Y 2 x 2 x 0,8,
max. 50 m Length)
Without using a battery, set up a connection from the input emergency
power monitoring to "+ 24 V DC"!
Mains connection supplied by the costumer 230 V AC, 50 Hz
Figure 3.4-4: Installing the power supply unit (stabilized) - external control unit
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
+ 2 4 V DC
49
5044745
+ 2 4 V DC
0 V
+ 24 V DC
EN